G-541 - 08/23/1994 - VILLAGE CODE - Ordinances ORDINANCE 94-BI-BO-G-541 AN ORDINANCE AMENDING CHAPTER 5 OF THE CODE OF ORDINANCES OF THE VILLAGE OF OAK BROOK RELATING TO BUILDINGS AND BUILDING REGULATIONS WHEREAS, the Village President and Board of Trustees have heretofore established rules and regulations for the construction, alteration, repair and conversions of building within the Village of Oak Brook; and WHEREAS, said provisions have been codified as Chapter 5 of the Code of Ordinances of the Village of Oak Brook; and WHEREAS, the Village President and Board of Trustees deem the amendment of said regulations to be in the best interest of the public health, safety and welfare; and WHEREAS, section 5/1-3-2 of Chapter 65 of the Illinois Compiled Statutes specifically authorizes the adoption of codes and public records by reference; and WHEREAS, the codes and portions thereof herein adopted have been filed in the office of the Village Clerk and available for public use and inspection and have been on file for a period in excess of 30 days prior to the passage of this ordinance as required pursuant to the provisions of section 5/1-3-2 of Chapter 65 of the Illinois Compiled Statutes; NOW, THEREFORE, BE IT ORDAINED BY THE PRESIDENT AND BOARD OF TRUSTEES OF THE VILLAGE OF OAK BROOK, DU PAGE AND COOK COUNTIES, ILLINOIS as follows: Section 1: That the provisions of the preamble hereinabove set forth are hereby adopted as though fully set forth herein. Section 2: That Section 5-1 of the Code of Ordinances of the Village of Oak Brook be and is hereby amended to read as follows: 115-1. Codes adopted by reference. ' a) There are hereby adopted by reference the following regulations governing all single-family residential buildings and appurtenances, multi-family residential buildings and appurtenances, and all other buildings and structures hereinafter erected, installed, altered, converted, remodeled or structurally repaired, demolished, moved, or their use or occupancy established or changed collectively to be known as the Oak Brook Building Code. 1. The BOCA National Building Code, 12th Edition (1993) published by the Building Officials and Code Administrators International, Inc. Ordinance 94-BI-BO-G-541 Amending Chapter 5 of the Code Relating to Buildings and Building Regulations Page 2 2. The City of Chicago Electrical Code (1993-4) known as Chapters 14-8, 14-12, 14-16, 14-20, 14-24, 14-28 and 14-32 of the Chicago Building Code. 3. The City of Chicago Plumbing Code (1993-4) known as Chapters 11-8 and 13-168 of the Chicago Building Code. 4. BOCA National Mechanical Code, 8th Edition (1993) published by the Building Officials and Code Administrators International, Inc. 5. The Safety Code for Elevators and Escalators, 1990 Editions, published by the American Society of Mechanical Engineers. b) The Oak Brook Building Code is amended and changed in the following respects: 1. All fees that are stipulated in Section 112.3.1 of the BOCA Code shall be those specified in Section 5-7 of this Code of Ordinances. 2. All fines and penalties stipulated in Sections 112.3.1, 116.4 and 117.2 of the BOCA Code shall be those specified in Section 1-8 of the Code of Ordinances. 3. The Board of Appeals described in Section 121.2 shall be comprised of the membership of the Village Board at the time of said appeal. 4. Automatic sprinkler systems shall be installed and maintained in full operating condition in all parts of all buildings, and structures as specified in Chapter 6, Article III of this Code of Ordinances. 5. All fees specified in the Chicago Electrical Code shall be superseded and replaced by those set forth in Section 5-7 of this Code of Ordinances. 6. All fees specified in the Chicago Plumbing Code shall be superseded and replaced by those set forth in Section 5-7 of this Code of Ordinances. i 7. The City of Chicago Plumbing Code adopted pursuant to Section 5.1 (3 hereof) is amended as follows: i) Section 13-168-320 regarding lead pipe is deleted and not adopted. ii) Section 13-168-705 a and b are deleted. iii) Section 13-168-306 is amended by adding thereto the following: The use of 4" P.V.C. plastic pipe is also permitted. Ordinance 94-BI-BO-G- 541 Amending Chapter 5 of the Code Relating to Buildings and Building Regulations Page 3 iv) Table 13-168-710A is amended by adding the following note: Not over two (2) water closets or two (2) bathroom groups shall be allowed on three (3) inch P.V.C. pipes in single- family detached dwellings. V) Section 13-168-540 is amended by adding thereto the following: Sump or receiving tanks constructed of fiberglass shall be permitted in single-family detached dwellings. 8. All fees, fines and penalties stipulated in the BOCA National Mechanical Code shall be superseded and replaced by those set forth in Sections 5-7 and 1-8 of this Code of Ordinances. C) In addition to the requirements of the Oak Brook Building Code, plumbing fixtures and any replacement plumbing fixtures shall comply with the following standards of water use. Water closet, tank type: Maximum 3.5 gallons (13.2 liters) per flush. Water closet, flushometer: Maximum 3.0 gallons (11.4 liters) per flush. Urinal, tank type: Maximum 3.0 gallons (11.4 liters) per flush. Urinal, flushometer: Maximum 3.0 gallons (11.4 liters) per flush. Shower head: Maximum flow 4.0 gallons (15.1 liters) per minute. Special purpose shower heads, where necessary, may be exempt from this requirement upon approval of the building commissioner. Lavatory sink faucets: Maximum flow 4.0 gallons (15.1 liters) per minute. The maximum rate of flow for lavatory sink faucets is measured with both hot and cold water supply fully opened. Public lavatories. Faucets or lavatories located in restrooms intended for public use shall be of self-closing type. i Water pressure-reducing valves. When internal (water) system pressure exceeds 60 psi (413.69 pascals) pressure-reducing valves shall be installed to reduce the pressure to a maximum of 50 psi (344.74 pascals) in residential dwelling units and other uses where the reduced pressure is compatible with the owner's requirement. This requirement for the installation of pressure-reducing valves does not apply to fire protection water uses. Section 3: The Village Clerk is authorized and directed to publish this Ordinance in pamphlet form. Ordinance 94-BI-BO-G-541 Amending Chapter 5 of the Code Relating to Buildings and Building Regulations Page 4 Section 4: This Ordinance shall be in full force and effect from and after its passage, approval and publication in pamphlet form in the manner required by law. PASSED THIS 23rd day of August , 1994. Ayes: Trustees Bartecki, Calzaretta, Kenny and McInerney Nays: None Absent: Trustees Payovich and Shumate Abstain: None APPROVED THIS 23rd day of August 1994. ddwt1l A, Ae4o — Village President ATTEST: f.� Village Clerk - Approved as to Form: Village Attorney Published 5-26-94 Pamphlet form 10, Date Paper