Loading...
BCG Restroom Renovation Drawingsco co O a Copyright © 2016 KLUBER, INC. NOTES DETAIL NUMBER—::::::,* DRAWING NUMBER � 1 — INDEX OF DRAWINGS � G100 COVER SHEET, GENERAL NOTES, SYMBOLS, & DRAWING INDEX G201 ACCESSIBILITY &MOUNTING INFORMATION ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS SET FORTH BY IBC 2009 EDITION AND SHALL CONFORM TO ALL OTHER APPLICABLE MUNICIPAL, DETAIL NUMBER 23 STATE, AND FEDERAL REGULATIONS INCLUDING THE ILLINOIS ACCESSIBILITY CODE DRAWING NUMBER A7.19 z (1997) AND THE AMERICANS WITH DISABILITIES ACT. 0 DETAIL NUMBER DRAWING NUMBER 2 6 9.16 5 3 A. GENERAL 1. 2. 3. 4. 5. NOTES B: MISCELLANEOUS AND DEMOLITION NOTES ALL CONTRACTORS ARE REQUIRED TO VISIT THE SITE AND BE KNOWLEDGEABLE 1. COORDINATE PENETRATIONS AND/OR SLEEVES REQUIRED IN WALLS, FLOORS, REGARDING EXISTING CONDITIONS AND THEIR EFFECT ON THE PROPOSED WORK. CEILINGS OR ROOFS FOR MECHANICAL AND ELECTRICAL WORK REQUIRED BY CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR, ANY CONDITIONS REQUIRING ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS.O MODIFICATION BEFORE PROCEEDING WITH THE PROJECT. 2. SEAL WITH UL APPROVED MATERIALS PENETRATIONS OF DUCTWORK, CONDUIT NOTIFY THE OWNER'S REPRESENTATIVE A MINIMUM OF 72 HOURS PRIOR TO THE AND PIPES THROUGH FIRE -RATED ASSEMBLIES, TO MAINTAIN THE RATING INTERRUPTION OF ANY UTILITY. INTEGRITY OF THOSE ASSEMBLIES. PROVIDE FIRE DAMPERS AS INDICATED ON THE DRAWINGS. PROTECT AND KEEP IN SERVICE ACTIVE UNDERGROUND UTILITIES, PIPES, OR CONDUITS, WHETHER INDICATED ON THE DRAWINGS OR NOT, UNLESS SPECIFICALLY CALLED FOR TO 3. SEAL WITH ACOUSTICAL SEALANT PENETRATIONS OF DUCTWORK, CONDUIT BE REMOVED, RELOCATED, OR DISCONNECTED AND ABANDONED. AND PIPES THROUGH NON -RATED FLOORS, FULL -HEIGHT WALLS/PARTITIONS, ACOUSTICALLY INSULATED WALLS/PARTITIONS, AND SOUND -RATED CONTRACTORS AND SUBCONTRACTORS SHALL COORDINATE THEIR WORK WITH THAT OF WALLS/PARTITIONS, TO MAINTAIN THE ACOUSTICAL INTEGRITY OF THOSE OTHER TRADES. ASSEMBLIES. NO WORK WILL BE PERMITTED TO BE INSTALLED WITHOUT RECIPT AND SUBSEQUENT 4. APPLY APPROPRIATE & COMPATIBLE SEALANT MATERIALS AS REQUIRED TO REVIEW OF FULL AND COMPLETE SUBMITTALS BY THE ARCHITECT/ENGINEER. SEPARATE DISSIMILAR METALS, FILL GAPS IN EXISTING ASSEMBLIES OR < ic 00 0 rn v { '� `4 1 v u)co G "� '� Q ' ti� �� sv Co 0 A210 A310 A800 A900 MEP210 MEP310 DEMOLITION FLOOR AND REFLECTED CEILINGO PLANS - GOVERNMENT CENTER FLOOR PLANS AND REFLECTED CEILING PLANS - GOVERNMENT CENTER ROOM FINISH SCHEDULE INTERIOR ELEVATIONS DEMOLITION FLOOR PLANS - GOVERNMENT CENTER FLOOR PLANS - GOVERNMENT CENTER R: - - o LO L C E .o o C , co E - �- �- Y 0° DETAIL NUMBER DRAWING NUMBER 1 A6.05 COLUMN NUMBER 26 LOCATION ELEVATION100'-0" T 1ST FLR. 6. WHERE NEW AND EXISTING ASSEMBLIES MEET DO NOT SCALE DRAWINGS, DIMENSIONS INDICATED TAKE PRECEDENCE OVER SCALE.REQUIRED BY THE SPECIFICATIONS. OR WHERE OTHERWISE ROOM NUMBER 204 r 7. VERIFY ALL DIMENSIONS AND ELEVATIONS IN THE FIELD. WHERE DISCREPANCIES ARE 5. BRING ANY UNFORESEEN OR CONFLICTING CONDITIONS TO THE IMMEDIATE FOUND BETWEEN DIMENSIONS OR ELEVATIONS SHOWN AND ACTUAL FIELD CONDITIONS, ATTENTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE NOTIFY ARCHITECT/ENGINEER. WORK. r m PROJECT BUTLER GOVERNMENT CENTER DOOR NO. NEW 203.2 8. WHERE CONFLICTS MAY EXIST BETWEEN THE REQUIREMENTS OF PORTIONS OF THE 6. REPAIR, PATCH, OR REPLACE FINISH MATERIALS OR VISIBLE ASSEMBLIES CONTRACT DOCUMENTS, THE GREATER QUANTITY, HIGHER QUALITY OR MORE STRINGENT THAT ARE SOILED, CUT OR DAMAGED IN ANY FASHION DURING THE COURSE REQUIREMENT SHALL GOVERN. THEREFORE, BY EXECUTING A CONTRACT FOR OF THE WORK. PERFORM PATCHING SUCH THAT EDGES BLEND INTO CONSTRUCTION, THE CONTRACTOR AGREES THAT, IF IT RAISED NO QUESTIONS CONTIGUOUS SURFACES SMOOTHLY, MATCHING TEXTURE AND COLOR OF REGARDING SUCH CONFLICTS DURING THE BIDDING PROCESS, AND IN THE ABSENCE OF ADJACENT SURFACES. A CLARIFYING ADDENDUM ISSUED DURING THE BIDDING PROCESS, IT HAS VOLUNTEERED DOOR NO. EXISTING 0 Zo RESTROOM RENOVATIONSrn 112 OAK BROOK ROAD Cn Z NOMINAL THICKNESS CONSTRUCTION TYPE SPECIAL CONDITION 8 I TO COMPLY WITH THE MORE EXPENSIVE REQUIREMENT AS PART OF ITS BASE BID AND OAK BROOK, IL 6 O IS NOT ENTITLED TO ANY ADDITIONAL COMPENSATION TO RESOLVE THE CONFLICT. KEYNOTE 15.211 9. THE CONTRACT DOCUMENTS REQUIRE THE CONTRACTOR TO FURNISH AND INSTALL IDENTIFICATION COMPLETE PRODUCTS, SYSTEMS AND SERVICES. BY EXECUTING A CONTRACT FOR CONSTRUCTION, THE CONTRACTOR AGREES THAT THE DRAWINGS SET FORTH THE DESIGN INTENT AND, THEREFORE, MAY NOT EXPRESSLY DEPICT EVERY LENGTH, SEGMENT, PIECE, PART, COMPONENT OR UNIT OF A PRODUCT, SYSTEM OR SERVICE. THE CONTRACTOR FURTHER AGREES THAT, AS PART OF ITS BID, IT MUST FURNISH AND INSTALL EVERY LENGTH, SEGMENT, PIECE, PART, COMPONENT OR UNIT OF A PRODUCT, SYSTEM OR SERVICE AND, CONSEQUENTLY, THE CONTRACTOR IS NOT ENTITLED TO ANY ADDITIONAL COMPENSATION FOR ANY LENGTH, SEGMENT, PIECE, PART COMPONENT OR UNIT OF A PRODUCT, SYSTEM OR SERVICE BECAUSE IT IS NOT EXPRESSLY DEPICTED HEREIN. OWNER ARCHITECT/ ENGINEER THE VILLAGE OF OAK BROOK 1200 OAK BROOK ROAD OAKBROOK IL 6 KLUBER ARCHITECTS + ENGINEERS 1 0 UM WAY AVE.AVE . H BATAVIA ILLINOIS 60510 TEL 630-406-1213 FAX 630-406-9472 WWW. kl �u be ri n c. com O Z w 0 0 ~ W O � O O O Q N m W a QYO J O W Y O m 0 LUQ m � 04 ° a J O > WINDOW TYPE IDENTIFICATION XO TOILET ACCESSORY IDENTIFICATION ❑A STANDARD ABBREVIATIONS SPOT ELEVATION � o ® - AT A B _ ANCHOR BOLT ABR ABRASIVE AT -(1) - ACOUSTIC TILE CEILING (TYPE) AFF - ABOVE FINISH FLOOR AFG - ABOVE FINISH GRADE ADD'N - ADD TON ADD'L _ADDITIONAL ADJ ADJACENT ADJT - ADJUSTABLE AL - ALUMINUM ALT - ALTERNATE EXP - EXPANSION EXP CONST _ EXPOSED CONSTRUCTION FD FLOOR DRAIN FDN - FOUNDATION FE - FIRE EXTINGUISHER FEC - FIRE EXTINGUISHER CABINET FIN - FIN SH OSE CABINET FLR _FLOOR FRT FIRE RETARDANT TREATED (RATED) FUR CHN L - FURRING CHANNEL FTG - FOOTING GA - GAUGE PL - PLATE PL LAM _ PLASTIC LAMINATE PL PLASTER PLB'G - PLUMBING PLB G CONTR - PLUMBING CONTRACTOR PLYWD - PLYWOOD PVC -POLYVINYL CHLORIDE PL -(1) _GYPSUM PLASTER (TYPE) R OR RAD RADIUS R - RISER RD - ROOF DRAIN RO - ROUGH OPENING as a CONCRETE PLAN MASONRY IN CONCRETE MASONRY IN PLAN (RUNNING BOND) CONCRETE MASONRY IN PLAN (STACK BOND) ANCH - ANCHOR AP - ACCESS PANEL APPROX - APPROXIMATE GALV - GALVANIZED GEN CONTR - GENERAL CONTRACTOR GC - GENERAL CONTRACTOR RF (1) - RUBBER FLOORING (TYPE) RH - RIGHT HAND REF - REFERANCE ASPH - ASPHALT GL - GLASS REINF - REINFORCING STONE MASONRY IN PLAN AUTO AVG BSMT BD - AUTOMATIC - AVERAGE -BASEMENT - BOARD GYP DB -1 - GYPSUM WALL BOARD (DRYWALL)(TYPE) GYP PL- 1 - GYPSUM PLASTER (TYPE) H -HIGH HD - HEAVY DUTY REQ'D - RM - SF -SQUARE SI - REQUIRED ROOM FOOT SQUARE INCH Q O RAKED JOINT IN PLAN CTRL JOINT IN PLAAEXP. N BITUM BLDG BLK'G BM - BITUMINOUS/BITUMASTIC - BUILDING - BLOCKING (WOOD) - BEAM HD - HARD HDNR - HARDENER HD WD -(1) - HARD WOOD (TYPE) HDWRE - HARDWARE SK - SS - SSK - SQ - SINK STAINLESS STEEL SERVICE SINK SQUARE LL O L.�Lj BRICK MASONRY IN SECTION DETAIL B. M. BT STL BRG BRKT BRK BTM BTW'N CJ CAB CEM PL- CT PAV-�13 CIPC - BENCH MARK PL - BENT STEEL PLATE - BEARING - BRACKET - BRICK - BOTTOM - BETWEEN - CONSTRUCTION/CONTRACTION JOINT -CABINET 1 - CEMENT PLASTER (TYPE) - CERAMIC PAVER TILE (TYPE) - CAST- IN- PLACE CONCRETE HGT - HEIGHT HM - HOLLOW METAL HP - HIGH POINT HORIZ - HORIZONTAL HTG - HEATING HVAC - HEATING/VENTILATING/AIR CONDITIONING IN - INCH ID - INSIDE DIAMETER INCL -INCLUDE (D) INSUL - INSULATION OR INSULATING JT - JOINT KD - KNOCK DOWN SCHED - SEAL/HDNR - SEC - SHT - SIM - SOG - SPEC - SPC'G - SPK'R -SPEAKER STN - STD - STD WGT - SCHEDULE SEALER/HARDENER SECTION SHEET SIMILAR SLAB ON GRADE SPECIFICATION(S) SPACING STN STANDARD STANDARD WEIGHT W 0 Q J j > BUILDING CODE DATA CONCRETE MASONRY IN SECTION DETAIL 2009 INTERNATIONAL BUILDING CODE 2009 INTERNATIONAL MECHANICAL CODE 2014 ILLINOIS STATE PLUMBING CODE 2008 NATIONAL ELECTRIC CODE � i i� i �� STONE MASONRY IN SECTION DETAIL CLG CLR CO CMU COL COMB COMP COMPT'D - CEILING - CLEAR - CLEAN OUT - CONCRETE MASONRY UNIT - COLUMN - COMBINATION -COMPRESSIBLE - COMPACTED L - LONG LAM - LAMINATED LAV - LAVATORY LH - LEFT HAND LP - LOW POINT LGT WGT - LIGHTWEIGHT LL -LIVE LOAD LLH - LONG LEG HORIZONTAL STL - STRUCT - SUSP - SYM - T - T&G - T/B -TOP T/C - STEEL STRUCTURAL OR STRUCTURE SUSPEND(ED) SYMMETRICAL TREAD TONGUE AND GROOVE OF BEAM TOP OF CURB STEEL IN SECTION DETAIL 2009 INTERNATIONAL PROPERTY MAINTENANCE CODE 2009 INTERNATIONAL EXISTING BUILDING CODE 2009 INTERNATIONAL FUEL GAS CODE 2009 INTERNATIONAL ELECTRICAL CODE 2012 INTERNATIONAL ENERGY CONSERVATION CODE ILLINOIS ACCESSIBILITY CODE -CURRENT EDITION LOCAL AMENDMENTS TO THE ABOVE CODES DISCONTINUOUS WOOD BLOCKING IN SECTION CONC - CONCRETE CONC OPNG - CONCRETE OPENING COND - CONDITION LLV - LONG LEG VERTICAL LVR - LOUVER MO - MASONRY OPENING T/F - T/S - T/STL - TOP OF FOUNDATION TOP OF SLAB TOP OF STEEL m CONTINUOUS WOOD BLOCKING IN SECTION CONT - CONTINUOUS MT - METAL THRESHOLD T/W - TOP OF WALL CONTR CPT- 1) CT -(1 - CONTRACT (OR) - CARPET (TYPE) - CERAMIC TILE (TYPE) MAS'Y - MASONRY MAT'L - MATERIAL MAX - MAXIMUM TB (4) - TOM - TYP - TACKBOARD (LENGTH) TOP OF MASONRY TYPICAL FINISHED WOOD IN SECTION DETAIL CTR CTR SK CTS CUH CUV DIA DIM DN DR DWG'S DTL DWL'S - COUNTER - COUNTER SINK - CENTER(S) - CABINET UNIT HEATER - CABINET UNIT VENTILATOR - DIAMETER - DIMENSION - DOWN - DOOR - DRAWINGS - DETAIL - DOWELS MB -(16) - MARKERBOARD- (LENGTH) MECH - MECHANICAL MECH CONTR - MECHANICAL CONTRACTOR MFR - MANUFACTURER MIN - MINIMUM MISC - MISCELLANEOUS MSB - MOP SERVICE BASIN (SINK) MT(D) - MOUNT(ED) MTL - METAL NIC - NOT IN CONTRACT NOM - NOMINAL NTS - NOT TO SCALE UNO - VBC - VBS - VCT - VEN PL (1) - VERT - W - W/ - W/0 - WCG - WD - WDN - UNLESS NOTED OTHERWISE VINYL BASE COVED VINYL BASE STRAIGHT VINYL COMPOSITION TILE VENEER PLASTER (TYPE)Z VERTICAL WIDE OR WIDTH WITH WITHOUT WALL CORNER GUARD WOOD WINDOW o cn Ln > w L LU o c L� z w O o CO RIGID BOARD INSULATION SEALS & CERTIFICATES RIGID BOARD INSULATION ARCHITECT'S MECHANICAL ENGINEER'S ELECTRICAL ENGINEER'S SEAL SEAL SEAL I HAVE PREPARED, OR CAUSED TO BE PREPARED UNDER MY DIRECT SUPERVISION, THE ATTACHED PLANS L(ROOFING) BATT INSULATION EA - EACH NO - NUMBER WGT - WEIGHT AND SPECIFICATIONS AND STATE EJ - EXPANSION JOINT OA - OVERALL WP - WATER PROOF THAT TO THE BEST OF MY EL - ELEVATION ELEC - ELECTRIC/ELECTRICAL ELEC CONTR - ELECTRICAL CONTRACTOR ELEV - ELEVATOR EMBED - EMBEDMENT EMER - EMERGENCY EP PNT - EPDXY PAINT EQ -EQUAL EW - EACH WAY EWC - ELECTRIC WATER COOLER EWH - ELECTRIC WATER HEATER ER -(26) - EXHIBIT RAIL (LENGTH) EXIST - EXISTING OC - ON CENTER OD - OUTSIDE DIAMETER OF - OUTSIDE FACE OPN G - OPENING OPP - OPPOSITE OPP HD - OPPOSITE HAND PSF - POUNDS PER SQUARE FOOT PSI -POUNDS PER SQUARE INCH PT - PRESSURE TREATED PTN, - PARTITION PAV T - PAVEMENT PC - PIECE PFM - PERMANENT FLOOR MAT WWF - WSB - WELDED WIRE FABRIC WALL SERVICE BASIN GYPSUM BOARD KNOWLEDGE AND BELIEF, AND TO THE EXTENT OF MY CONTRACTUAL OBLIGATION, THEY ARE IN COMPLIANCE WITH IBC 2009 EDITION, THE ENVIRONMENTAL BARRIERS ACT AND THE ILLINOIS ACCESSIBILITY CODE. KLUBER, INC. ILLINOIS PROFESSIONAL DESIGN FIRM LICENSE #184-001284 JOB NO. DRAWN CHECKED APPROVED 16-172-1038 JAB CJH CJH ACOUSTICAL CEILING PANEL SHEET TITLE BITUMINOUS CONCRETE IN SS CION PAVING COVER GENERAL SYMBOLS DRAWING SHEET, NOTES, AND INDEX o�o�o�o�o�o 0 0 0 0 o AGGREGATE BALLAST, FILL OR BACKFILL IN SECTION SHEET NUMBER THE MATERIALS, ABBREVIATIONS, AND DRAFTING SYMBOLS LEGEND ARE EACH AN ALL INCLUSIVE MASTER LIST USED BY THIS FIRM. THE INCLUSION OF THESE LEGENDS THESE DOCUMENTS DOES NOT IMPLY THAT ALL THE SYMBOLS OR MATERIALS INCLUDED INTO IN THESE "G" SERIES "G" SERIES "G" SERIES "A" SERIES "MEP" SERIES "MEP" SERIES Gl 00 UNDISTURBED EARTH LEGENDS ARE INCORPORATED INTO THIS PROJECT. EARTH BACKFILL E 0 0 M C U) 2 U- c w U O 00 Copyright © 2016 KLUBER, INC. 12" 3'-0" MIN. CONTROL i AREA � 5'-0" MIN. � / • O i o i 3'-0" MIN. - i i I I I I z / � 12" 41 L-------� 4'-0" MIN. I (CLEAR to o „ FLOOR SPACE — CLEAR FLOOR SPACE L INTERMEDIATE GUARD , SPACING TO NOT ALLOW FRONT AND SIDE APPROACH PASSAGE OFA 4" SPHERE Z W 0 > N O r co 1'-6" rCONTROL 4'-8" MIN. W/ WALL MOUNTED W.C. w w NOTE: SAME HEIGHT GUARD AND 0 M o c.l AREA L = 0° U) z HANDRAILS IS NOT o - o M 4'-11" MIN. 1W/ FLR. MOUNTED W.C. Q m w N — — ALLOWED. o M of o 0 Z C c6 �o 6 Y N 1 STALL AT END OF ROW w o CO'co o C W Y m a T + 12" T _ N 4' 0" MIN. _ ¢ 1'-0" 1 EXTNSN TREAD ` 1 c� MIN. �_ " 1°_ 0' o ® WALL DEPTH C) rV) � RAIL N 1" THE CLEAR SPACE a — RISER a BETWEEN AND WALLTOR OTHERHE SURFACE TO BE 1-1/2" HANDRAIL EXTENSIONS TRANSFER SHOWER 7 ;2 N.T.S. N.T.S. HEIGHT 00 11"MIN. HANDRAILS SHALL RETURN TO A WALL, GUARD, TREAD WALKING SURFACE, OR DEPTH SHALL BE CONTINUOUS TO C) I CLEAR FLOOR SPACE) THE HANDRAIL OF AN 4'-0" MIN. ADJACENT STAIR FLIGHT. ALTERNATE DOOR 0 1'-7" MAX. LOCATION — — — — — — SIDE APPROACH Z - 4" MAX. 2'-8" MIN. CLEAR FLOOR SPACE 0 TY P STAIR INFORMATION N o i r r O' MIN. . — 2 40 "4 Z (RAMP INFORMATION SIMILAR N.T.S. 1 — CLEAR FLOOR SPACE) - c 1'-5" MIN. °O z N o O I Lo L Z —�Z la 6 3'-5%" MIN. W CONTROL MOUNTING HEIGHTS xQ `n LATCH APPROACH 1'-0" MAX 11 ONLY, OTHER E I 3'-3" TO 3'-5" APPROACHES co DRAIN PIPES FLOOR SPACE, 4'-0" MIN. 4'-4" MIN. O INSULATE J TO PREVENT CONTACT Q X — —CLEAR 4'-8" MIN. W WALL MOUNTED W.C. / O � z 4'-11" MIN. W/ FLR. MOUNTED W.C. o I � z N STANDARD STALL Y F O Q N 6" MAX. 8" MIN. m a 1'-5" MIN. FRONT APPROACH - Q 0 J 3'-3" TO 3'-5" 3'-3" TO 3'-5" OOWLL 0Y 0 0 E L E VAT O R 2 THRESHOLDS 9 LAVATORY 6 O N.T.S. N.T.S. N.T.S. Q Y 3'-6" MIN. z �/ i N J r O 1'-0" MA 1'-0" MAX 3'-6" MIN. O > 4'-0" MIN. 3 - O z — �n 1 z Ln 1 IIL, z M z z M r n 1 -0 MAX 7 z ® TOILET PAPER N DISPENSER i� o M TOILET PAPER N M z DISPENSER I o Q SRC 100 O 1 1 O ® N MOUNTING HEIGHTS o MOUNTING HEIGHTS o CLEAR FLOOR SPACE Ln ^ LO I i� U. L I 1 O W V w o 3'-0" MIN. r_ r 3'-0" MIN. J � X W LO 0 1'-5" TO 1'-7" a — I o I OO ih M p OO O x < x Z Z ME o o a, I CV o o a, CV z l� z O I n r " �, CV MOUNTING HEIGHTS MOUNTING HEIGHTS INTERIOR SIGNAGE 8 6" MAX. 8" MIN. FIRE EXT. CABINETS DRINKING FOUNTAIN 5 SINGLE -USER TOILET ROOM 4 MULTI-USER TOILET ROOM 3 GENERAL NOTES N.T.S. N.T.S. N.T.S. N.T.S. N.T.S. w w cn �z — — — — — — — — W W ----- ----- co o" O V V Of � o I LaiQ o Z� 4'-6" rm z ' 3'-0" MIN. x UIt z �� �i I co 0 4'-0" MIN. 1 z IF X=5'-0" `o z � � � 2'-0" 3'-6" MIN. � 1-6 in 00 ti r u 2 -0 ;�, IF X=4'-6" o I 1 a 0 1 JOB NO. 16-172-1038 E -------J �-------� ------ 0 I N �`�, 1'-0" DRAWN JAB IF DOOR HAS CLOSER CHECKED CJH z C) I I AND LATCH I APPROVED CJH SHEET TITLE ACCESSIBILITY REQUIREMENTS L — — — — — — I — J 4'0.-0" MIN. SHEET NUMBER PARALLEL DOORS G2012 DOOR CLEARANCES N.T.S. O 0 co N 0 N _ LO co co O a Copyright © 2016 KLUBER, INC. KEYNOTES 1.000 KEYNOTES TYPICALLY ARE NOT DUPLICATED WITHIN A GIVEN DETAIL. CONTRACTOR IS TO ASSUME THAT AN UN -KEYED ITEM IS TO BE THE SAME AS THE KEYNOTED ITEM WITHIN THE SAME DETAIL. _ 2.092 EXISTING DRYWALL CEILING; PATCH AS REQUIRED PRIOR TO REPAINTING. 2.101 EXISTING CEILING ACCESS HATCH. - 2.454 DEMOLISH EXISTING INTERIOR WALL CONSTRUCTION: LOW WALL BELOW COUNTERTOP. 2.460 DEMOLISH EXISTING INTERIOR SPECIALTY ITEM: AS INDICATED. 2.461 DEMOLISH EXISTING INTERIOR SPECIALTY: TOILET PARTITION. 2.464 DEMOLISH EXISTING INTERIOR SPECIALTY: TOILET ACCESSORY; AS INDICATED. 2.467 DEMOLISH EXISTING INTERIOR CONSTRUCTION: CASEWORK; AS INDICATED. 2.472 DEMOLISH EXISTING INTERIOR WALL FINISH: CERAMIC TILE & BACKER BOARD BACK TO BLOCK CONSTRUCTION. 2.474 DEMOLISH EXISTING INTERIOR FLOOR FINISH: CERAMIC TILE. - 2.477 DEMOLISH EXISTING INTERIOR FLOOR FINISH: RESILIENT BASE. _ 2.478 DEMOLISH EXISTING INTERIOR FLOOR FINISH: CERAMIC TILE BASE. AM JAL 2.481 DEMOLISH EXISTING INTERIOR CEILING FINISH: DRYWALL AND SUSPENDED FURRING. 2.483 DEMOLISH EXISTING INTERIOR CEILING FINISH: DRYWALL SOFFIT AND FRAMING. 2.483 2.498 2.492 2.498 2.483 2.492 DEMOLISH EXISTING MECHANICAL SYSTEM COMPONENT: CEILING DIFFUSER/GRILLE. 2.493 SALVAGE EXISTING FIRE PROTECTION SYSTEM COMPONENT: SPRINKLER HEAD ESCUTCHEONS; REFER TO FIRE o 2.498 PROTECTION DRAWINGS FOR ADDITIONAL INFORMATION. "> o00 o 2.494 DEMOLISH EXISTING FIRE PROTECTION SYSTEM COMPONENT SCHEDULED FOR RELOCATION: SPRINKLER HEAD; co ci N v REFER TO FIRE PROTECTION DRAWINGS FOR ADDITIONAL INFORMATION.. 2 Ogg 2.496 DEMOLISH EXISTING PLUMBING FIXTURE: AS INDICATED. o M o 2.494 2.494 2.498 DEMOLISH EXISTING LIGHT FIXTURE; REFER TO ELECTRICAL DRAWINGS. r, (DW E 00 TYP. TYP. TYP. 2.493 2.500 REMOVE AND SALVAGE EXISTING ELECTRICAL SYSTEM COMPONENT: BASEBOARD DIFFUSER; REFER TO ELECTRCIAL TYP. DRAWINGS. r- -----•---- -- - -� --- --- -- .-•-- s • -----z -- - ---- r -- .- ------1---•» , • 2.601 CORE FLOOR IN LOCATION SHOWN TO ALLOW FOR NEW FLOOR DRAIN INSTALLATION CAREFULLY REMOVE .I EXISTING 1X1 CEILING TILES AT THE LOWER LEVEL CEILING AREAS TO ALLOW FOR DRAIN INSTALLATION of F1 %% AND CONNECTION TO EXISTING SANITARY PLUMBING. REPLACE 1X1 CEILING TILES AT LOWER LEVEL AFTER 2.481 �' }. :• ' ';•' } .;I I.'• 1 ; ' 2'481 - FLOOR DRAIN INSTALLATION. CONTRACTOR SHALL REVIEW EXISTING LOWER LEVEL CEILING TILE INSTALLATION PRIOR TO SUBMITTING HIS BID TO VERIFY FULL EXTENT OF SCOPE. WHOLE ROOM 1' �% `; rl• c I �' f �� '' WHOLE ROOM ! U056 ===--j-----------_---� : 11• 2.101 .11 -----= --- --- IL 'll ••� X09(? '• •• • I' �� • UE��7' • " • 1' 2.498 , � 1.11 ': '• %11'. 11 11 1 f 2.498 ;; ' U098 ;; r.; 2.498 2.498 �.. FIXTURE AND `, ; '• �� ; FIXTURE AND V/ SURROUND�,-, I `1 SURROUNDcn %% 1 __u ------ J ,,, :.z 2.460 O CEILING ACCESS HATCH Z W w 2.493 2.092 TYP. TYP. O NORTH NORTH O F_ 0QN W 0 O to J m�� O a0W DEMOLITION CEILING PLAN-U096-UO97 DEMOLITION CEILING PLAN-U056-UO57 �Yw O O SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" Y Na J _jT_O GENERAL NOTES 'r O 1. REFER TO DRAWING G100 FOR PROJECT GENERAL NOTES. 2. UNLESS NOTED OTHERWISE, WHERE EXISTING FLOOR, WALL AND CEILING SURFACES ARE SCHEDULED TO RECEIVE FINISHES, DEMOLISH EXISTING FINISH MATERIALS (EXCEPT PROPERLY ADHERED PAINT) AND SALVAGE SURFACE -MOUNTED ITEMS; PROPERLY PREPARE SURFACES TO RECEIVE NEW FINISHES; REINSTALL SURFACE -MOUNTED ITEMS AT NEW LOCATIONS DETERMINED BY OWNER UNLESS SPECIFIC LOCATIONS ARE INDICATED ON DRAWINGS. O 3. STORE SALVAGED ITEMS AS DIRECTED BY OWNER AND GENERAL CONTRACTOR. U 4. PROTECT SALVAGED ITEMS FROM DAMAGE UNTIL INCORPORATED INTO THE WORK OR UNTIL MOVED TO OWNER'S PERMANENT STORAGE. O 5. ADDITIONAL DEMOLITION/ RECONSTRUCTION AND REMOVAL/REPLACEMENT OF ARCHITECTURAL AND STRUCTURAL W ELEMENTS IS REQUIRED TO COMPLETE THE WORK OF THIS PROJECT. COORDINATE WITH ARCHITECTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL DRAWINGS, AND PROVIDE DEMOLITION/RECONSTRUCTION AND REMOVAL/REPLACEMENT OF ARCHITECTURAL AND STRUCTURAL ELEMENTS AS REQUIRED TO COMPLETE THE WORK SHOWN ON THOSE DRAWINGS. J 2.461 2.601 2.496 2.496 2.601 2.461 6. AT CEILING GRID AREAS TO BE DEMOLISHED, TEMPORARILY SUPPORT LIGHT FIXTURES, REMAINING CEILING GRID AND TYP. TYP. TYP. TYP. TYP. TYP. 2.500 PANELS, AND OTHER CEILING MOUNTED COMPONENTS THAT ARE TO INDICATED TO REMAIN IN PLACE AS PART OF J THE PERMANENT WORK. y ��\ 2.461 TYP. ALL TOILET ACCESSORIES, 2.464 %.�\ ALL TOILET ACCESSORIES, ENTIRE ROOM >; >; ;' �� �, 2.464 \\ ENTIRE ROOM --• -- r-i---i-----i- BMs _I_ _, ■I_ _,_ �_�--_ •---•-_ -_ _I_ 1 I 1 1 1 1 1 1 1 1 1 II S s S s/ T- T -T -T -T -T-11 i ------ - --•_-1•_"i _ i _ a - i - a - i - A 1 1 1 1 1 1 1 1 1 1 1 ALL TOILET ACCESSORIES, 2.464 a* 2.496 >\ > . 2.474 ;<'� r ,^ a >\ , •� WHOLE ROOM ' '>;" �'>;' �'>!: ,,' � ' ,'' ..� • •` �,'' ,`>,' •`�,,' •`>,,' 1 1 1 1 1 1 1 1 1 1 1_1__1__1__1__1__1__ 1_ 1__,__�__�__�_ �__�_ �� I -- --- 1 a l I I Il - - - - - - _ _ _._, ,_,_,_, ENTIRE ROOM �' \` TYPICAL AT ALL WET WALL 2.478 i 1 ` 2-472 `0 I__I-_I_,v-r.1_ L_I__I__I__I__I__I_,,�_I_ __I_______ y _ 1 I I I I I 141 I I I I I I I f I I^� ' ' - I�r.` __ _ _ _ _'•� Il r I/^� I �� I I I I I I ( I I I Il '^, ,%C TILE LOCATIONS IN THIS ROOM 2.496----------------=- v L -I- -I- -I- -I- -I- x_1__1__1 _I__�_!__�_ __1_ 1 I I 1•,1 I 1 `t-�- I I 1 --�� �--,--,--,----- --,- , -,--,1 ' + y _i i_i ------ _� =� I 1 ,,,- I Il 1 I -, -, -, - ----; - --�--�-�- •`� 2.496 '� `\ ALL TOILET ACCESSORIES ALL 2.464 ENTIRE ROOM _ I I I I Ir! �� �>�_>�_�>•>{as _ - _ >{spa I I I >, 4$ TYP. I I I I I I I I I I I I I I I I i►�------------------ +'---- k -- - fI�I-��1•�I- �i1 7-,-1-+-1-+-1-+-1-14r-r- � � � � � � I I I I I I I l y l I- I f - - - - -- - - --------SIL •� v I I 3.- rl TYP. �� ' \,>�\\>� ` >�/ ` o� 2.496 \'• q� I I I I I I I _\ FraL-1--I>•i--------------�--�#-----,----,----,��--,'J if 111;31 b1 f M I I I ® I lI f411---r<t--------------'r�------'- '--'- '--'-(SL1_: � � � � � � � ��� _, - _, - _, - _, -1-1-1-1-1-1-1-1r -r I U I I I I _ � _: _ � _: _, _, _L-1-1_1_1_1_1_11 . In11; r�� T-1, ,>� TYP. ,`. Ji --1 `. , ■■■ , .� ,. ,w ` ' V�\ ' .�\ •/' 14 ' , ' '>' V, I I----'--•-'----'--'--' f_Iayi_I_i__I__I__ I__I__I__I__I__I_14�I____I I 1 I II I I I I L _ _ _ _ _ _ _, I I I I, ,,` Ilc� 1 I I I I I 1_1_1_1_1_1_1_1r T\7� I I I I ` ' ' >, s `, „'' ,'�% ~' TYPICAL AT ALL WET WALL 2.464 A �,1 „� x.`, 1 N �V � � \ ' 2.472 ROOMSCHEDULE O O F-I-,--I-.---�---�---�---�--- - - - - ` _V LW_i_W_i_W_i_W_i_W_i 11 I I rr-r-r- 1` > ..- .;' > �' TYP. 1, o -. "°o �'' LOCATIONS IN THIS ROOM TILE L i- I_ I I I I I �� 4 I 11 I Illi_ I I Ir �_�_ _�_4rr_r_r_ I ti ice`;-•-J_J J_J_J1_ 1 2.464 1 L' -L -L_ L_L I ' rr-f=f I I I ,° ` - ' i %� @a8'�. i'�•/: `L'\, �'�' Alk 2.461 ' @ COUNTERTOP : }'' " X 1 - --ti-�-ti-�-til �'_ = : r'- ':�` a------�-�r ' 2.467 1 1 , ,5. 0 >. �I>\- >. Q AND SUPPORTS �' ' n '-�'�� nP ->' .. . RM. N0. ROOM NAME RM. N0. ROOM NAME COUNTERTOP 2.467 AND SUPPORTS �--------�-�� L TOILET �I� I ,y 1 I I I I Ir 11090 r y I I I 1 1 I, , I,i - - - - 4- 4'_1111 U 8 �- -�- -� 1 1 1 1 1 1 1 , 1 1 1 1 1; ���r-}�I 1 1 I_y_*_�_�_�_�_�_�_�_�_� ACCESSORI I I I I li ; O 4 L_H_N_H_N_H_N } '� r- - - 2.467 COUNTERTOP AND SUPPORTS >; ;>; ,;>, >; \c� ,J Ye~. `: ,v'• , 2.496 x ;� • 2.496 i. %� ' �° 'pa i `` �+ U056 ' EXISTING WOMEN'S TOILET ROOM 1 1 11 -�_ ENTIRE ROOM -�t . �- _ • -� -1 1 -� -1 OrL-L-r- TYP. >;' >; >; _ Y .%f: %. ;: \` TYP. �,>. \ �� �, . (` . �` ��\, U057 EXISTING MEN'S TOILET ROOM 2.454-------err-r- > > ; e ^� .� ' \ 'o�\ / '\ ;: \� 2 464 w - I 1 I I I I 1 ------err-r-r- U0. ' ` ,• `�,•2.464 Yo�;: \�-�;: , TYP. TYP. \'; \'; �•@'� j �\ `�" ,�. ' \`-�-�- \UNDER COUNTER111IIII 2.467 CABINET-' -� 44 4- - -�-�-�E 1 I 1 I I I I , -�- -�- -�--�r'-�- - , I I I I r 2.472 ALL WALLS, 4:, q" '�� ,,?: >: '� �y�. �� ~ " • • `• W 1 1 -J-4-4-J-4-i FH -L -H -L -H -L- L -r-r- ENTIRE ROOM, _�-�- , ` II •' ` ' �` '" ;< " `2:496; ' >s U096 EXISTING MENS TOILET ROOM v 1 _ _ _ FULL HEIGHT ,'' + > ,: \ - ,-~ a . '' ' U097 EXISTING WOMEN'S TOILET ROOM 00 cd did- , , `' , , `,; U098 EXISTING JANITOR CLOSET - c o 2.500 2.474 2.472 2.474 ---=y---1-y------==-�=-- � Q co N 0 N _ LO co co O a Copyright © 2016 KLUBER, INC. KEYNOTES 1.000 KEYNOTES TYPICALLY ARE NOT DUPLICATED WITHIN A GIVEN DETAIL. CONTRACTOR IS TO ASSUME THAT ANEm UN -KEYED ITEM IS TO BE THE SAME AS THE KEYNOTED ITEM WITHIN THE SAME DETAIL. _ 2.083 EXISTING HOLLOW METAL DOOR FRAME AND WOOD DOOR. REPAINT DOOR FRAME ON BOTH SIDES OF DOOR OPENING. REFER TO ROOM FINISH SCHEDULE. 2.092 EXISTING DRYWALL CEILING; PATCH AS REQUIRED PRIOR TO REPAINTING. 8.310 ACCESS DOOR: SIZE AS SPECIFIED. T 9.056 LATEX LEVEL FLOOR IN AREA INDICATED TO ALLOW FOR NEW FLOOR DRAIN INSTALLATION. REFER TO PLUMBING DRAWINGS FOR EXACT LOCATION OF FLOOR DRAIN. 9.292 GYPSUM BOARD: PATCH EXISTING GYPSUM BOARD AROUND NEW WASTE COMBO RECEPTACLE, LEFT FROM LARGER _ DEMOLISHED SEMI-RECCESSED WASTE/PAPER TOWEL RECEPTACLE; PROVIDE ADDITIONAL FRAMING AS REQ. 9.293 GYPSUM BOARD: PATCH EXISTING GYPSUM BOARD FROM REMOVED SEMI -RECESSED TOILET ACCESSORY; PROVIDE AM ADDITIONAL FRAMING AS REQ. 9.303 PROVIDE 5/8" THICK MOISTURE RESISTANT GYPSUM BOARD AND CERAMIC WALL TILE WITH BACKER BOARD; 26.001 FULL WALL HEIGHT; REFER TO INTERIOR ELEVATIONS AND ROOM FINISH SCHEDULE. 9.510 ACOUSTICAL CEILING PANELS AND GRID. o 26.001 9.512 23.370 9.512 ACOUSTICAL CEILING ACCESSORY: EDGE TRIM; HEIGHT AS INDICATED. o E o co o 00 ° loll TYP. ci � D v C3 10.219 TOILET COMPARTMENT: CONFIGURATION AS INDICATED; MATERIAL AS SPECIFIED. o o M O3 .. 12.365 COUNTERTOP: SOLID SURFACING; 1-1/4 EDGE THICKNESS, U.N.O. C6 O co E 00 21.130 SPRINKLER PIPING/FITTING/HEAD TO BE RELOCATED TO NEW CEILING LOCATION - CENTER OF TILE. 21.130 21.132 TYP. 21.132 SPRINKLER HEAD TO REMAIN. VK f I N 8.512 23.370 MECHANICAL DIFFUSER/GRILLE: REFER TO MECHANICAL DRAWINGS. 10"23.373 EXISTING MECHANICAL SYSTEM COMPONENT. DIFFUSER/GRILLE TO REMAIN; REFER TO MECHANICAL DRAWINGS. 26.001 26.001 LIGHT FIXTURE: REFER TO ELECTRICAL DRAWINGS. TYP. 26.001 2.092 U056 23.373 TYP. TYP. 26.370 RE -INSTALL SALVAGED EXISTING ELECTRICAL COMPONENT: ELECTRIC BASEBOARD; REFER TO ELECTRICAL 21.130 TYP... DRAWINGS. TYP. U097 I U096 26.001 U098 26.001 TYP. 21.130 8.310 EX. V Z O CEILING SYMBOL LEGEND - ' U057 �. 26.001 Q SYMBOL DESCRIPTION SYMBOL DESCRIPTION 21.130 �., GYPSUM BOARD �0 FLOURESCENT LIGHT FIXTURE 24" X 48" TYP. d'o;lc .. 0 FLOURESCENT LIGHT FIXTURE 12" X 48" uj PLASTER FLOURESCENT LIGHT FIXTURE STRIP 9.510 26.001 23.373 2.092 21.132LIGHT TYP. TYP. TYP. TYP. ` ' '' ❑ FIXTURES 24"X24" FLOUR.; 12"X12" INCAN. ACOUSTICAL CEILING TILE : 12" X 12" SPECULAR CEILING GRID : 1" X 1" WITH FLOR. LGTS. 0 0 NORTH NORTH d O 0 o DOWN LIGHT FIXTURES : A B C D A: SPOT B: DOWN C: WALL WASHER D: SCONCE ACOUSTICAL CEILING TILE : ® �1 EXIT LIGHT FIXTURE 0 < M 24"X24" W 00� LIGHT TRACK FIXTURE J pp to - Y O J =124" ACOUSTICAL CEILING TILE : x 48" EMERGENCY LIGHT FIXTURE 0 0 O o Y ° a0 00 REFLECTED CEILING PLAN-U096-UO97 REFLECTED CEILING PLAN-U056-UO57 O 0 A SPRINKLER HEAD u SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" ACCESS PANEL: ®MECHANICAL DIFFUSER : SUPPLY GENERAL �/ J N i J° 24" X 24" : U.O.N. O r MECHANICAL DIFFUSER RETURN 0 EXPOSED METAL 1. REFER TO DRAWING G100 FOR PROJECT GENERAL NOTES. 2. IN STUD/GYPSUM BOARD PARTITIONS AND WALLS, PROVIDE 2X FIRE RETARDANT TREATED WOOD BLOCKING FOR w WALL -MOUNTED ITEMS REQUIRING MECHANICAL ANCHORAGE. 3. SPOT ELEVATIONS ARE DESIGNATED NOMINAL HEIGHTS ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. TOILET ACCESSORY SCHEDULE COORDINATE FINAL HEIGHTS OF CEILING ELEMENTS WITH INFORMATION CONTAINED ON STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL DRAWINGS. 0 4. PROVIDE GYPSUM BOARD HEADERS TO FORM VERTICAL SOFFITS AT CHANGES OF ACOUSTICAL CEILING HEIGHTS MOUNTING UNLESS NOTED OR DETAILED OTHERWISE. LL MARK DESCRIPTION CAT. NO. REMARKS HEIGHTS 5. PATCH ALL EXISTING DRYWALL SURFACES TO MATCH EXISTING FROM DEMOLITION AND NEW CONSTRUCTION, O SNAP-ON COORDINATE WITH DEMOLITION DRAWINGS. ❑A S.S. GRAB BAR - 36" 3800-36 FLANGE COVER SEE SHEET G201 W SNAP-ON ❑6 S.S. GRAB BAR - 42" 3800-42 FLANGE COVER SEE SHEET G201 S.S. GRAB BAR - 18" (VERTICAL) 3800-18 FLANGEOCOVER SEE SHEET G201 2.083 \ 2'-0"t L.l 10'-1t 2'-0f 8'-10%t 2'-0"t TYP. O a WALL MOUNTED SOAP DISPENSER 5001 -SS SURFACE 48" MAX. TO 56,,+ 16' 6 MOUNTED DISPENSER 12.365 5-9" 5-9" Sl NEW BACKER BOARD THIS WALL ONLY. NEW 61 9.303 CERAMIC TILE TO BE INSTALLED AT FULL" 40" TO BOTTOM \X PERIMETER OF ROOM. REFER TO ROOM ❑F CHANNEL FRAME MIRROR 0620 24 X 36 MAXIMUM 9.293 FINISH SCHEDULE AND ELEVATIONS DRAWINGS I 5 26.370 FOR MORE INFORMATION. , SFOs �G SANITARY NAPKIN DISPOSAL 0852 SURFACE MOUNTED 44" TO TOP MAX. 10.219 A ;H o B J G cj ° J B ° O 9.056 i -H C ❑J TOILET TISSUE DISPENSER 0264-1 SURFACE MOUNTED SEE SHEET G201 9.056 _ i M NEW BACKER BOARD THIS WALL J p 4 A900 �� p ONLY. NEW CERAMIC TILE TO BE ' INSTALLED AT FULL PERIMETER � G B �K AUTOMATIC PAPER TOWEL DISPENSER 2494 SURFACE 48" MAX. TO 5)- P sr- \ MOUNTED, 1 DISPENSER OPENING °s(o 00 10.219 ° 5 A900 600 o ° 0 ^� U056 �l1 9.303 OF ROOM. REFER TO ROOM ? FINISH SCHEDULE AND SURFACE ° 48 MAX. TO F �, 10.219 SI . OPP. N F 11 YY o �� ELEVATIONS DRAWINGS FOR MORE a WALL MOUNTED SOAP DISH 0720-Z MOUNTED DISH RIM ROOM SCHEDULE 9 292 T / SINFORMATION. AS ❑N SQUARE TOWEL BAR 7360-624 CONCEALED MOUNTING " 48 MAX. TO TOP OF BAR U096 p +i lilt" J G 9.292 x � �'� % F B J D RM. NO. ROOM NAME RM. NO. ROOM NAME o o � ®lo i O o 10.219 o 6 A900 5 5'-2'f 09800T J 5'-1 ":0o F , �O G J o C �S SHOWER CURTAIN ROD 1224 CONCEALED U056 EXISTING WOMEN'S TOILET ROOM MOUNTING U057 EXISTING MEN'S TOILET ROOM 9.292 9.293 F 12.365 ®� ° `hyy A �' w cn z SHOWER CURTAIN HOOK 1200 SHU ® Q, 0 w i 9.293 ro U097.1 _ - - U096.1 X 12.365 / �\ o ���' / ��- 12.365 \X `ti H O F r� xi Pio p U096 U097 EXISTING MEN S TOILET ROOM EXISTING WOMEN'S TOILET ROOM w cn w Z � 00 D v VINYL SHOWER CURTAIN 1200 V ANTI -BACTERIAL ANTI -FUNGAL ANTI -MILDEW FLAME RETARDANT iv A900 0°° U098 EXISTING JANITOR CLOSET c 2.083 2.083 / 1 ®o° ❑T AUTOMATIC PAPER TOWEL DISPENSER/ WASTE RECEPTACLE COMBO UNIT 204692A-6 SEMI -RECESSED 61" TO TOP OF UNIT VERIFY W U / MAN JF. m 9.303 9.303 T F 26.370 �� r ENTIRE ROOM, ENTIRE ROOM, EU FREESTANDING OPEN WASTE RECEPTACLE 0813 FREE STANDING 13 X 30 X 13 KEY PLAN o 0 ALL WALLS ALL WALLS61 ,,---- f _70,,2-7� TOILET ACCESSORY GENERAL NOTES JOB NO. 16-172-1038 DRAWN JAB 2.083 9.292 1. A.S.I. CATALOG NUMBERS ARE USED FOR REFERENCE ONLY, UNLESS OTHERWISE NOTED. CHECKED CJH 2. MOUNTING HEIGHTS PER ADA -AG (AMERICAN'S WITH DISABILITIES ACT ACCESSIBILITIES GUIDELINES). APPROVED CJH 3. MOUNTING HEIGHTS ARE FROM FINISHED FLOOR TO HEIGHT INDICATED. SHEET TITLE FLOOR PLANS & U096-UO97 NORTH NORTH U056-UO57 REFLECTED CEILING PLANS - GOVERNMENT TOILET ACCESSORY REMARKS CENTER SHEET NUMBER NORTH 1. BOBRICK CATALOG NUMBERS, USED FOR REFERENCE ONLY. FLOOR PLAN -U096 -U097 FLOOR PLAN - U056 -U057 3 1/4" 1'-0" 1/4" 1'-0" � SCALE: = SCALE: = C;nnvrinht n gniR KI I IRFR INC: Q 0 N N 0 N r - L LI w U) I— p W w LL.I Z � � U 00 0 p o p o m 00 T r r r Lf) � o JOB NO. 16-172-1038 DRAWN JAB CHECKED CJH APPROVED CJH SHEET TITLE DOOR, FRAME & HARDWARE SCHEDULES TOILET ACCESSORY SCHEDULE SHEET NUMBER jollill 0 l co co 0 a ROOM FINISH SCHEDULE FINISH TYPES ��_c ROOM NO. ROOM NAME FLOOR BASE WALLS CEILING REMARKS AREA FIN. DESCRIPTION AREA FIN. DESCRIPTION -- _ NORTH SOUTH EAST WEST FLOOR F1 RESILIENT TILE: 12°X12° CEILING Cl ACP: 24"X24" (MTL. SUSP. SYS. SS -1) FIN. CC. FIN. CC. FIN. CC. FIN. CC. FIN. CC. FIN. CC. FIN. CC. F2 CERAMIC TILE: 12"X12" U056 EXISTING WOMEN'S TOILET ROOM F3 CFTA B3 CBTA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA EX -C2 (P3) PC 1,3,5,7,9,10 C2 SUSP. GYP. BD.: %"THK.; MOISTURE RESISTANT; MTL.FRAMING F3 CERAMIC TILE: 6"X24° U057 EXISTING MEN'S TOILET ROOM F3 CFTA B3 CBTA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA EX -C2 (P3) PC 1,3,5,7,9,10 F4 RUBBER FLOORING/STAIR TREAD/RISERS C3 SUSP. GYP. BD.: %"THK.; MTL. FRAMING -TYPE 'X' DRYWALL F5 EPDXY PAINT C4 EXPOSED CONSTRUCTION -FINISHED U096 EXISTING MEN'S TOILET ROOM F3 CFTA 133 CBTA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA Cl ACTA 3,4,5,7,9,10 F6 FOOT GRILLE A U097 EXISTING WOMEN'S TOILET ROOM F3 CFTA 63 CBTA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA Cl ACTA 3,4,5,7,9,10 F7 RESILIENT SHEET C5 EXPOSED CONSTRUCTION - UNFINISHED U098 EXISTING JANITOR CLOSET EX EX EX EX EX EX EX C6 NOT USED BASE B1 RESILIENT BASE AS SPECIFIED: 4" COVE B2 CERAMIC TILE COVE BASE; 3" X 12" C7 CERAMIC TILE B3 CERAMIC TILE COVE BASE; 6" X 12" C8 ACP: 24"X24" (CLEAN ROOM VL) o C) co r_ .o L - > COE CD C) 00 0 o M CO C co - M a v Y PAINT P1 LATEX -"PEARL" WALLS W1 CERAMIC TILE; 12"X24" P2 LATEX - "SEMI -GLOSS" W2 SOLID SURFACING PANELS P3 LATEX - "FLAT" W3 GYPSUM BOARD; 5/8" THICK; MOISTURE RESISTANT P4 ENAMEL - "SEMI -GLOSS" COLOR CODE SCHEDULE P5 PREFINISHED: REFER TO SPECS. W4 CERAMIC TILE; 12"X12" P6 EPDXY - "SEMI -GLOSS" AREA CODE MANUFACTURER COLOR/CAT NO. AREA CODE MANUFACTURER COLOR/CAT NO. CERAMIC FLOOR TILE CFTA AMERICAN OLEAN; ARBOR HOUSE #AH52-WARM CHERRY; 6" X 24" WOODGRAIN SOLID SURFACE SSA AVONITE COLOR: #K3-8343 PEARL GLASS FG1 1/4" SAFETY GLASS; TEMPERED; CLEAR STAIN S1 STAIN & FINISH: REFER TO SPECS. FG2 1/4" WIRED; CLEAR SSC INTEGRAL LAVATORY SINK BOWLS COLOR: 1-8010 BONE SG1 1" INSULATED GLASS UNITS, TINTED SG2 1" INSULATED GLASS UNITS, CLEAR SG3 1" INSULATED SPANDREL UNITS CERAMIC WALL TILE CWTA AMERICAN OLEAN; RAPPORT; WALL TILE #RP04 HARMONY BEIGE; 12X24 PLASTIC LAMINATE PLA WILSONART 7919K-78 - AMBER CHERRY - PREMIUM CWTB AMERICAN OLEAN; FORTIFY MOSAICS WITH STONE; SQUARE PATTERNS COLOR - CRATER; 4" HIGH ACCENT TILE AS SHOWN ON DRAWINGS CERAMIC BASE TILE CBTA AMERICAN OLEAN; RAPPORT; COVE BASE TILE #P-36C9T; 6"HX12"L; MATCH WALL TILE COLOR PAINT PA SHERWIN WILLIAMS SW 6150 - UNIVERSAL KHAKI FINISH REMARKS Z 0 Q O Z W 0 0 UJ O F 1 0 0 m 0 LL 0 W J J Y O Q c') 0N m w Q Y Y J a0 O Y Om0 W a m Q0 J Na O ,r PB SHERWIN WILLIAMS SW 7048 -URBAN BRONZE PC SHERWIN WILLIAMS SW 7006 - EXTRA WHITE 1. EXISTING AND NEW DRYWALL CEILINGS AND SOFFITS (C2 AND C3) TO BE PAINTED P3, COLOR PC. 2. W2 FOR WALLS ABOVE SHOWER BASIN TO 8 FEET HEIGHT, W1 FOR ALL OTHER WALLS IN ROOM; REFER TO PLANS. 3. REPAINT ALL EXISTING METAL DOOR FRAMES IN PROJECT SCOPE P4, COLOR PB. 4. PLASTIC LAMINATE BASE CABINETS TO BE COLOR PLA. 5. TOILET PARTITIONS TO HAVE BAKED ENAMEL FINISH, COLOR ALMOND. 6. TOILET PARTITIONS TO HAVE BAKED ENAMEL FINISH, COLOR TO BE DETERMINED BY OWNER FROM FULL RANGE OF MANUF. STANDARD COLORS. 7. CERAMIC TILE WALL GROUT TO BE COLOR WTGA; CERAMIC TILE FLOOR GROUT TO BE COLOR FTGA. 8. CERAMIC TILE WALL GROUT TO BE COLOR WTGA; CERAMIC TILE FLOOR GROUT TO BE COLOR FTGB. 9. CERAMIC WALL TILE ACCENT BAND, COLOR CWTB. REFER TO INTERIOR ELEVATIONS. 10. SOLID SURFACE COUNTERTOP TO BE COLOR SSA, INTEGRAL BOWLS TO BE COLOR SSC. 11. SOLID SURFACE COUNTERTOP TO BE COLOR SSB, INTEGRAL BOWLS TO BE COLOR SSC. 12. REPAINT ALL EXISTING METAL DOOR FRAMES IN PROJECT SCOPE P4, COLOR TO MATCH EXISTING DOOR FRAME COLOR. 13. CERAMIC FLOOR TILE IN PORTION OF ROOM NEAR LAVATORIES. SEE FLOOR PLAN FOR TILE BREAK POINT. WALL GROUT WTGA BOSTIK H183 -ALPINE WHITE -SANDED GROUT FLOOR GROUT FTGA BOSTIK #H136 - BRICK - EPDXY GROUT CEILING ACTA USG; ECLIPSE CLIMA PLUS #76775 - SLT; BEVELED TEGULAR. FTGB BOSTIK #H141 - FLASH WALNUT - EPDXY GROUT SHOWER SURROUND SHSA AVONITE: FOUNDATIONS #F1-9036 SANDSTORM GENERAL NOTES 1. REFER TO A300 SERIES REFLECTED CEILING PLANS FOR CEILING HEIGHTS. 2. REFER TO ROOM FINISH SCHEDULE FOR SPECIFIC DOOR AND FRAME FINISHES. Q 0 N N 0 N r - L LI w U) I— p W w LL.I Z � � U 00 0 p o p o m 00 T r r r Lf) � o JOB NO. 16-172-1038 DRAWN JAB CHECKED CJH APPROVED CJH SHEET TITLE DOOR, FRAME & HARDWARE SCHEDULES TOILET ACCESSORY SCHEDULE SHEET NUMBER jollill 0 l co co 0 a Q co N co 0 N r - co co O a INTERIOR ELEVATION 6 SCALE: 1/4" = 1'-0" INTERIOR ELEVATION 5 SCALE: 1/4" = 1'-0" INTERIOR ELEVATION 4 SCALE: 1/4" = 1'-0" INTERIOR ELEVATION ()) SCALE: 1/4" = 1'-0" INTERIOR ELEVATION ( )2 SCALE: 1/4" = 1'-0" INTERIOR ELEVATION ( ) SCALE: 1/4" = 1'-0" C;nnvrinht n gniR KI I IRFR INC: KEYNOTES 1.000 KEYNOTES TYPICALLY ARE NOT DUPLICATED WITHIN A GIVEN DETAIL. CONTRACTOR IS TO ASSUME THAT AN UN—KEYED ITEM IS TO BE THE SAME AS THE KEYNOTED ITEM WITHIN THE SAME DETAIL. 6.420 ARCHITECTURAL WOOD CASEWORK: PLASTIC LAMINATE; BASE CABINETS. 6.440 ARCHITECTURAL WOOD CASEWORK: PLASTIC LAMINATE; FILLER PANEL, SIZE AS REQUIRED. 9.313 CERAMIC WALL TILE: FIELD COLOR. 9.314 CERAMIC WALL TILE: ACCENT BAND. 9.316 CERAMIC TILE ACCESSORY: BULLNOSE CORNER TRIM — METAL; REFER TO SPECIFICATIONS. 10.219 TOILET COMPARTMENT. CONFIGURATION AS INDICATED; MATERIAL AS SPECIFIED. 10.280 TOILET ACCESSORY: TYPE AS INDICATED; REFER TO SCHEDULE. 12.365 COUNTERTOP: SOLID SURFACING; 1-1/4" EDGE THICKNESS, U.N.O. 12.369 COUNTERTOP SKIRT BOARD: SOLID SURFACING; 3/4" THICK; 5" DEEP. 12.377 COUNTERTOP ACCESSORY. METAL SURFACE MOUNTED COUNTER SUPPORT BRACKET, REFER TO SPECIFICATIONS. 22.400 PLUMBING FIXTURE: REFER TO PLUMBING DRAWINGS. O �, co o E 00 26.001 LIGHT FIXTURE: REFER TO ELECTRICAL DRAWINGS. o N o M o i 0 7 GENERAL NOTES 1. REFER TO DRAWING G100 FOR PROJECT GENERAL NOTES. 2. REFER TO A300 SERIES REFLECTED CEILING PLAN DRAWINGS FOR CEILING HEIGHTS. 3. COORDINATE CEILING HEIGHTS WITH SECTIONS AND DETAILS. 4. COORDINATE LOCATIONS OF WALL—MOUNTED ELECTRICAL ITEMS WITH ARCHITECTURAL ITEMS TO ENSURE NO OVERLAP. 5. REFER TO FLOOR PLANS FOR TOILET ACCESSORY TYPES AND LOCATIONS. 6. NOT ALL TOILET ACCESSORIES ARE SHOWN ON THE INTERIOR ELEVATIONS, FOR CLARITY. REFER TO FLOOR PLANS FOR FULL SCOPE OF TOILET ACCESSORIES. H Q 0 Z W 0 0 H W J 0 H W w cn p w W w Z 2 in 3: U 00 o p o p o m 000N Y Y O J OHO u- 0 - m WQw QOY J N Q _j T JOB NO. 16-172-1038 DRAWN JAB CHECKED CJH APPROVED CJH SHEET TITLE INTERIOR ELEVATIONS SHEET NUMBER A900 co co 0 a Copyright © 2016 KLUBER, INC. KEYNOTES 21.100 REMOVE SPRINKLER HEADS AND PROVIDE TEMPORARY CAP FOR NEW SPRINKLER HEAD CONNECTION. 22.100 REMOVE PLUMBING FIXTURE. PROVIDE TEMPORARY CAP ON WATER, WASTE AND VENT PIPES. 22.101 REMOVE GALVANIZED STEEL WATER PIPES SUPPLYING FIRST FLOOR FIXTURES BACK TO ISOLATION VALVE OR AT COPPER PIPE CONNECTION. 22.102 REMOVE PLUMBING FIXTURE AND ALL ASSOCIATED GALVANIZED STEEL WATER PIPES. PROTECT SANITARY AND VENT PIPING FOR CONNECTION TO NEW PLUMBING FIXTURES. 22.107 REMOVE GALVANIZED STEEL WATER PIPE SUPPLYING EXISTING ELECTRIC WATER COOLER. EWC TO REMAIN IN T PLACE. 611 I 23.100 REMOVE EXHAUST GRILLE. PROVIDE TEMPORARY CAP ON DUCTWORK UNTIL CONNECTION TO NEW GRILLE. 4" 26.100 REMOVE EXISTING LIGHT FIXTURE AND DISPOSE ACCORDING TO SPECIFICATIONS. DISCONNECT AND PROTECT - _Dj CO(e) EXISTING BRANCH CIRCUITRY TO REUSE WITH NEW LIGHT FIXTURE. AM 26.101 REMOVE AND PROTECT COVER PLATE DURING CONSTRUCTION. REINSTALL UPON COMPLETION OF ARCHITECTURAL ------- �� WORK. ~ 4" 0 26.102 DISCONNECT, PROTECT AND REINSTALL EXISTING FIRE ALARM NOTIFICATION APPLIANCE. 5" DS UP 4" DN 26.103 DISCONNECT, PROTECT AND REINSTALL EXISTING ELECTRIC BASEBOARD HEAT. o o E CD c co co N 0 N C) N 22.102 4"V UP 4„ D D T U 0 = 0 m L - - TYP 4" VTR W/INCR(e) 4" V UP I 4>� n - o - M M 4" SAN DN (e) I 8 ° E 0 23.100 TYP 23.100 TYP 1-1/2" SAN DN (e) �+ ••� - 4"W UP 21.100 -_______ - WC --------- --- I k W a\ 26.100 1-1/2"W UP TYP •---• -, ,=_; I EG 0 1 - =_= - EG --- c 1`� \'� 3/4" HW/CW FROM BELOW SAN 0 14/14 UP, -,: -____'====y f- „ I "ti - 3/4 HW & CW UP 3/4 HW & CW UP " 3/4 HW/CW a ; \,` LAV%" FROM BELOW ' -, % ,� EG •-, -=_: ,, ` , t-+-+ �'� - - „ 1 __='- - i �, EG \\%i - �` , 1 ., „ , --- OS AV 26.102 U 26.102 I t ,, ; -- ----------- 1-1/2 ------- _� 1-1 2 W IP / r UP 111/2"CW DN 2" "z' 22.101 ' .102 r I C 8- y ._.----- " P-- ---------� �' i �•_ _-- r 3'll� SAN/ -�rrl[ i 1-1 /2"CW y, ,I �, ,,FI(y1 LAV U 9 MB(e) m ' ' ' () }� 1li 1-V C �,, 1212 ,- „, '' „ 3 4 HW 22.101 & CW UP „ z� =' EF5-1 e) EG(e U098 FR BELOW I 1'; If ��-� ; 22.102 i 2 i -�--- 1 50 CFM JIL - --- -I TYP1L i i 22.101 26.100 J i TYP o 26.100 TYP 1-1/2"% 1 ~ cun) V♦ ti 5 -5-7(e) EWC(e) I I i i Q + r I 8 z 2 ' .101 ti . 261 1 1 1 1 3/4 -CW - - O 22.107 1 1 1-1/2\11 % ° I i ~ - I * 2" V UP 1„ 4 V DN 3/4" HW DN Q F I -Dc 1-1/4" CW DN > 2-1/2" = I � t - - 46� 3/4" 1-1 /4" Lu r t i Q N W LO m0 J YoJ O 0W �YW DEMOLITION FLOOR PLAN-U096-UO97 DEMOLITION FLOOR PLAN -LOWER LEVEL O O SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" Y Na J JPO GENERAL NOTES O 'r O m Q O LL O Lu c� Q J J_ 26.100 % - 4" VTR(e) 4" V(e) 26.101 I K c I , \ 1 1 , , , ,a (e) 26.102N� U056 �� 11 •\ WC \\ �+ s � 1 / - 26.100 ROOM SCHEDULE WC\� I 1 22.100 RM. N0. ROOM NAME RM. N0. ROOM NAME TYP\\ �; °:,;�, ;/ , ,:� WC LAV, U056 EXISTING WOMEN'S TOILET ROOM LAV '°\ ,� '- - ^.\. \ U057 EXISTING MEN'S TOILET ROOM � w 26.101 , \ w z LAV, - 111' 22.100 U096 EXISTING MENS TOILET ROOM LU Of LU � Z Lu TYP U097 EXISTING WOMEN'S TOILET ROOM Ln 00 c=i ( ) \x U098 EXISTING JANITOR CLOSET -00 o EWC(e) o pg U 7 . / -`�\ 26.101 r LAV 26.101 26.1°°----, KEY PLAN 26.102 26.100 3/4" JOB NO. 16-172-1038 2" DRAWN CEC/ATR CHECKED DDW/MTK 3/4" APPROVED DDW SHEET TITLE - - - - - - - U096-UO97 DEMOLITION FLOOR U056-UO57 PLANS - 3" GOVERNMENT CENTER 3/4" SHEET NUMBER NORTH MEP21 0 DEMOLITION FLOOR PLAN - U056-UO57 1/4" 1'-0" SCALE: = 3 Q co N m M 0) co 0 co co O a Copyright © 2016 KLUBER, INC. KEYNOTES 21.200 PROVIDE NEW SPRINKLER HEAD, MATERIAL AND LABOR FOR INSTALLATION IN NEW CEILING CONFIGURATION. 22.200 PROVIDE NEW PLUMBING FIXTURE. CONNECT TO EXISTING WATER, SANITARY AND VENT PIPING. 22.201 PROVIDE COPPER WATER PIPE FROM EXISTING COPPER WATER OR VALVES NEAR LOCATIONS SHOWN TO NEW FIXTURE LOCATIONS ON FIRST FLOOR. 22.202 PROVIDE FLOOR DRAIN, WASTE AND VENT PIPES IN RESTROOMS. PROVIDE CONNECTION INTO EXISTING WASTE AND VENT PIPING. 22.203 PROVIDE NEW PLUMBING FIXTURE. PROVIDE CONNECTION TO NEW WATER PIPES AND TO EXISTING WASTE AND VENT PIPES. PROVIDE MATERIAL AND LABOR TO RECONFIGURE PIPES AS REQUIRED FOR NEW FIXTURES 22.207 PROVIDE NEW 1/2" COPPER PIPE WATER SUPPLY TO EXISTING ELECTRIC WATER COOLER.611 23.200 PROVIDE NEW EXHAUST GRILLE, ALL LABOR AND MATERIALS TO CONNECT TO EXISTING BRANCH DUCTWORK AND 4" NEW CEILING LOCATION. - _Dj CO(e) 26.200 REPLACE ALL OUTLET AND SWITCH COVERPLATES UPON COMPLETION OF ARCHITECTURAL WORK. A 26.201 PROVIDE AND INSTALL NEW LIGHT FIXTURE. REUSE EXISTING BRANCH CIRCUITRY. PROVIDE NEW CEILING 4" 0 MOUNTED OCCUPANCY SENSOR (MANUAL ON/AUTOMATIC OFF). EXTEND AS NECESSARY FOR A COMPLETE AND 5" DS UP 4" DN OPERATIONAL SYSTEM. SEE SPECIFICATIONS FOR LIGHTING FIXTURE SCHEDULE. o 26.202 REINSTALL FIRE ALARM NOTIFICATION APPLIANCE UPON COMPLETION OF ARCHITECTURAL WORK. C) co o 00 o 26.203 REINSTALL ELECTRIC BASEBOARD HEAT UPON COMPLETION OF ARCHITECTURAL WORK. C14 0 ;TT 4"V UP 4' C3 o o 4" VTR W/INCR(e) 4" V UP I 4> n - °' - o CD M 4" SAN DN (e) f' ''**�� I 8 Y W E 0 f 26.201 26.201 SAN DN (e) - 4"W UP NC C EG -1-1/2" 100 WC -1 WC -1 C ' F - - - - - - - - - - 22.202 - , `J� - -SAN 1-1 /�"ui i io o I 2 •201 22.203 TYP 1- " V �ZOT�p) o ° r2 ° 0 22.202 ^ 3/4„ HW/CW (2 I I I FROM BELOW �I, 26. S,,. +# 2" 1-1/2"UP TO - ----- -- - - 3/4" HW & CW UP UP TO FD ,r 2 „ 3/4 HW & CW UP 3/4" HW/CW 14/14 UP _ FD- L_1 22.203 2" 0- - 22.201 s FROM BELOW o ' LL=1 S o EG -1 o TYP os ) / „ 2 W "CW DN 22.2 2 NC C. 100 CFM C-2 (2 TYP) -1. 'A" m I 1-1/2" fUP 1-1/2" SM uN (e)� TYP. _ - 3" �' SAN } % m 14/1 12 12 MB(e) ; I 1-1 2" CW UPJ NCJ o L=1 J - 22.201 3/4" HW & CW UP 2„ 26.201 EF5- e) EG(e U09 - C 26.201 1 - - 50 CFM22.201 1-1/2" CW 23.200 - - 2.20 3/4" I 1 " FROM BELOW TYP TYP 3/4" :• J N -5-7(e) 11 Z 1-1/211 I 8" V C 26.200 0 EWC(e) -- C 1' I Q N " I 3/4 CWI- � NC - - . b/ 1-1/2 s. O 22.207 21.200 TYP ..� s 2" V UP _: 1 1„ 4" V DN 3/4" HW DN Q 4 F I - 1-1/4" CW DN 2-1/2" = t - - 3/4" 1-1 /4" uj r t 1 NORTH NORTH O z, Q N W0 Ln J mw a O 0 OY ow W< FLOOR PLAN -U096 -U097 3 LOWER LEVEL FLOOR PLAN 2 SCALE: 1/4 V-0" SCALE: 1/4 V-0" PLUMBING GENERAL NOTES a JTN ° PLUMBING FIXTURE SCHEDULE O O TAG DESCRIPTION COLD HOT WASTE VENT REMARKS 1. REFER TO DRAWING G100 FOR PROJECT GENERAL NOTES. WC -1 WATER CLOSET -FLUSH VALVE 1 - 4 2 ADAAG COMPLIANT 2. ALL SANITARY, WASTE AND STORM PIPES UP TO AND INCLUDING 3 INCHES SHALL SLOPE AT 1/4 INCH PER WC -2 WATER CLOSET -FLUSH VALVE 1" - 4" 2" FOOT, 4 INCHES AND LARGER SHALL SLOPE AT 1/8 INCH PER FOOT, UNLESS OTHERWISE NOTED. UR -1 URINAL -FLUSH VALVE 3/4" - 2" 1-1/2" ADAAG COMPLIANT 3. ALL PIPING IS SHOWN DIAGRAMMATICALLY AND DOES NOT SHOW ALL OFFSETS, DROPS AND RISES. THE L-1 LAVATORY -INTEGRAL TO COUNTER 1/2" 1/2" 1-1/2" 1-1/4" ADAAG COMPLIANT CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL MATERIAL AND LABOR FOR A COMPLETE AND WORKING SYSTEM. O 4. OBTAIN AND PAY ALL COSTS FOR PERMITS, LICENSES, CERTIFICATE FILING AND INSPECTIONS BY AUTHORITIES HAVING JURISDICTION. U. 1. ALL PLUMBING MATERIALS AND INSTALLATIONS SHALL BE IN STRICT ACCORDANCE WITH ALL STATE AND LOCAL PLUMBING RULES AND 5. EXISTING PIPING INDICATED ON THESE PLANS SHALL BE FIELD VERIFIED FOR EXACT LOCATIONS, QUANTITY AND REGULATIONS CURRENTLY IN EFFECT, GOVERNED BY THE ADMINISTRATIVE AUTHORITY HAVING JURISDICTION. PIPE SIZES. O 2. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF ALL TRAPS AND CLEANOUTS AS NECESSARY OF THE LOCALITY. 6. DO NOT CUT THROUGH STRUCTURAL ELEMENTS WHEN INSTALLING OPENINGS REQUIRED FOR ALL DUCTWORK, PIPING, W CONDUITS OR OTHER WORK. CONTRACTOR CUTTING THROUGH OR OTHERWISE DAMAGING THESE ELEMENTS WILL BE 3. THE OPENINGS IN WALLS FOR THE PASSAGE OF PIPES SHALL BE TOTALLY FIRE SEALED TO THE SATISFACTION OF THE PLUMBING RESPONSIBLE FOR ALL ASSOCIATED ENGINEERING FEES AND SUBSEQUENT RETRO-FIT/REINFORCING DEEMED INSPECTOR AND/OR THE AUTHORITY HAVING JURISDICTION. NECESSARY TO REINSTATE THE CONTINUITY OF THE DISRUPTED ELEMENTS. 7. COORDINATE ROUGH -INS FOR AND INSTALLATION OF PLUMBING FIXTURES WITH ACCESSIBILITY AND MOUNTING J INFORMATION CONTAINED ON ARCHITECTURAL DRAWINGS. J 8. DRAINAGE AND VENT SYSTEM SHALL BE PRESSURE TESTED WITH WATER OR AIR. 4" VTR(e) > B0 DIFFUSERS, REGISTERS AND GRILLES SCHEDULE 4" V(e) MARK MODEL SIZE NECK DAMPER MATERIAL REMARKS K EG -1 301FL 12/6 - OBD AL 1 FD(e) /11 1. MODEL BASED ON TITUS. U056 A-E W(yl `, 22.200 TYP ROOM SCHEDULE WC -2 22.200 IL TYP O WC -1 RM. NO. ROOM NAME RM. NO. ROOM NAME LL=1 1-1/2" V(e) U056 EXISTING WOMEN'S TOILET ROOM ' ° U057 EXISTING MEN'S TOILET ROOM ®° LL=1 UR -1 \ 26.201 w ✓®LU YP. 0 of w ° \ 26.203 K\ \ L=1 U096 U097 EXISTING MEN'S TOILET ROOM EXISTING WOMEN'S TOILET ROOM cn T � 00 L) o U098 EXISTING JANITOR CLOSET c o EWC(e) . TYP. OS -E U 7 26.201 L 26.200 0 ° TYP. TYP. 'C KEY PLAN 26.202 22.200 TYP. 3/4" 126.201 TYP JOB NO. 16-172-1038 1 2" DRAWN CEC/ATR 1 CHECKED DDW/MTK 3/4" APPROVED DDW SHEET TITLE - - - - - - - - U096-UO97 _ _ _ _ NORTH U056-UO57 FLOOR PLANS - GOVERNMENT 3" CENTER 3/4" SHEET NUMBER NORTH MEP31 0 FLOOR PLAN - U056-UO57 1/4" V-0" SCALE: =