BGC LLRestroom Renovations Drawings 91517
CD m 00 0 00 0 N Copyright © 2017 KLUBER, INC. GENERAL NOTES DETAIL NUMBER—:::::::* v INDEX OF D RAW I N G S DRAWING NUMBER 12.24 z G100 COVER SHEET, GENERAL NOTES, SYMBOLS, & DRAWING INDEX G201 ACCESSIBILITY & MOUNTING INFORMATION ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS SET FORTH BY IBC 2015 EDITION AND SHALL CONFORM TO ALL OTHER APPLICABLE MUNICIPAL, STATE, AND FEDERAL REGULATIONS INCLUDING THE ILLINOIS ACCESSIBILITY CODE DETAIL NUMBER DRAWING NUMBER 23 A7.19 (1997) AND THE AMERICANS WITH DISABILITIES ACT. DETAIL NUMBER DRAWING NUMBER 2 ::: 60 5 3 A. GENERAL NOTES B: MISCELLANEOUS AND DEMOLITION NOTES 1. ALL CONTRACTORS ARE REQUIRED TO VISIT THE SITE AND BE KNOWLEDGEABLE 1. COORDINATE PENETRATIONS AND/OR SLEEVES REQUIRED IN WALLS, FLOORS, A310 FLOOR PLANS AND REFLECTED CEILING PLANS A800 ROOM FINISH SCHEDULE A900 INTERIOR ELEVATIONS �= _- 2. 3. 4. 5. REGARDING EXISTING CONDITIONS AND THEIR EFFECT ON THE PROPOSED WORK. CEILINGS OR ROOFS FOR MECHANICAL AND ELECTRICAL WORK REQUIRED BY CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR, ANY CONDITIONS REQUIRING ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS. MODIFICATION BEFORE PROCEEDING WITH THE PROJECT. 2. SEAL WITH UL APPROVED MATERIALS PENETRATIONS OF DUCTWORK, CONDUIT NOTIFY THE OWNER'S REPRESENTATIVE A MINIMUM OF 72 HOURS PRIOR TO THE AND PIPES THROUGH FIRE -RATED ASSEMBLIES, TO MAINTAIN THE RATING INTERRUPTION OF ANY UTILITY. INTEGRITY OF THOSE ASSEMBLIES. PROVIDE FIRE DAMPERS AS INDICATED ON THE DRAWINGS. PROTECT AND KEEP IN SERVICE ACTIVE UNDERGROUND UTILITIES, PIPES, OR CONDUITS, WHETHER INDICATED ON THE DRAWINGS OR NOT, UNLESS SPECIFICALLY CALLED FOR TO 3. SEAL WITH ACOUSTICAL SEALANT PENETRATIONS OF DUCTWORK, CONDUIT BE REMOVED, RELOCATED, OR DISCONNECTED AND ABANDONED. AND PIPES THROUGH NON -RATED FLOORS, FULL -HEIGHT WALLS/PARTITIONS, ACOUSTICALLY INSULATED WALLS/PARTITIONS, AND SOUND -RATED CONTRACTORS AND SUBCONTRACTORS SHALL COORDINATE THEIR WORK WITH THAT OF WALLS/PARTITIONS, TO MAINTAIN THE ACOUSTICAL INTEGRITY OF THOSE OTHER TRADES. ASSEMBLIES. NO WORK WILL BE PERMITTED TO BE INSTALLED WITHOUT RECIPT AND SUBSEQUENT 4. APPLY APPROPRIATE & COMPATIBLE SEALANT MATERIALS AS REQUIRED TO REVIEW OF FULL AND COMPLETE SUBMITTALS BY THE ARCHITECT/ENGINEER. SEPARATE DISSIMILAR METALS, FILL GAPS IN EXISTING ASSEMBLIES OR O r Z v � rn O f O A ��, � 40 v i V CO '4 CO N MEP310 MECHANICAL, ELECTRICAL AND PLUMBING FLOOR PLANS, SCHEDULES AND DETAILS DETAIL NUMBER DRAWING NUMBER 1 - - - A6.05 C C E :o - :o M L - C - c o 20 .to L COLUMN NUMBER 26 LOCATION ELEVATION T 1ST FLR. � 100'-0" 6. DO NOT SCALE DRAWINGS, DIMENSIONS INDICATED TAKE PRECEDENCE OVER SCALE. WHERE NEW AND EXISTING ASSEMBLIES MEET REQUIRED BY THE SPECIFICATIONS. OR WHERE OTHERWISE ROOM NUMBER 204 D r (� 7. 8. VERIFY ALL DIMENSIONS AND ELEVATIONS IN THE FIELD. WHERE DISCREPANCIES ARE 5. BRING ANY UNFORESEEN OR CONFLICTING CONDITIONS TO THE IMMEDIATE FOUND BETWEEN DIMENSIONS OR ELEVATIONS SHOWN AND ACTUAL FIELD CONDITIONS, ATTENTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE NOTIFY ARCHITECT/ENGINEER. WORK. WHERE CONFLICTS MAY EXIST BETWEEN THE REQUIREMENTS OF PORTIONS OF THE 6. REPAIR, PATCH, OR REPLACE FINISH MATERIALS OR VISIBLE ASSEMBLIES CONTRACT DOCUMENTS, THE GREATER QUANTITY, HIGHER QUALITY OR MORE STRINGENT THAT ARE SOILED, CUT OR DAMAGED IN ANY FASHION DURING THE COURSE REQUIREMENT SHALL GOVERN. THEREFORE, BY EXECUTING A CONTRACT FOR OF THE WORK. PERFORM PATCHING SUCH THAT EDGES BLEND INTO CONSTRUCTION, THE CONTRACTOR AGREES THAT, IF IT RAISED NO QUESTIONS CONTIGUOUS SURFACES SMOOTHLY, MATCHING TEXTURE AND COLOR OF REGARDING SUCH CONFLICTS DURING THE BIDDING PROCESS, AND IN THE ABSENCE OF ADJACENT SURFACES. A CLARIFYING ADDENDUM ISSUED DURING THE BIDDING PROCESS, IT HAS VOLUNTEERED TO COMPLY WITH THE MORE EXPENSIVE REQUIREMENT AS PART OF ITS BASE BID AND IS NOT ENTITLED TO ANY ADDITIONAL COMPENSATION TO RESOLVE THE CONFLICT. c r m 0 rn z v PROJECT BUTLER GOVERNMENT CENTER LOWER LEVEL RESTROOM RENOVATIONS 1112 OAK BROOK ROAD Z O Q O z w DOOR NO. NEW DOOR NO. EXISTING 203.2 203.1X NOMINAL THICKNESS CONSTRUCTION TYPE SPECIAL CONDITION M8 b 9. THE CONTRACT DOCUMENTS REQUIRE THE CONTRACTOR TO FURNISH AND INSTALL KEYNOTE IDENTIFICATION 15,211 OAK BROOK,IL 60523 COMPLETE PRODUCTS, SYSTEMS AND SERVICES. BY EXECUTING A CONTRACT FOR O CONSTRUCTION, THE CONTRACTOR AGREES THAT THE DRAWINGS SET FORTH THE DESIGN INTENT AND, THEREFORE, MAY NOT EXPRESSLY DEPICT EVERY LENGTH, SEGMENT, PIECE, PART, COMPONENT OR UNIT OF A PRODUCT, SYSTEM OR SERVICE. THE CONTRACTOR FURTHER AGREES THAT, AS PART OF ITS BID, IT MUST FURNISH AND INSTALL EVERY LENGTH, SEGMENT, PIECE, PART, COMPONENT OR UNIT OF A PRODUCT, SYSTEM OR SERVICE AND, CONSEQUENTLY, THE CONTRACTOR IS NOT ENTITLED TO ANY ADDITIONAL COMPENSATION FOR ANY LENGTH, SEGMENT, PIECE, PART COMPONENT OR UNIT OF A PRODUCT, SYSTEM OR SERVICE BECAUSE IT IS NOT EXPRESSLY DEPICTED HEREIN. OWNER THE VILLAGE O OAK BROOK 1200 OAK BROOK ROAD OAK BROOK, IL 60523 O � w J WINDOW TYPE IDENTIFICATION TOILET ACCESSORY IDENTIFICATION STANDARD ABBREVIATIONS SPOT ELEVATION r �� o �� X00' ARCHITECT/ ENGINEER KLUBER ARCHITECTS + ENGINEERS 10 S. S H U MWAY AVE. BATAVIA ILLINOIS 60510 TEL 630-406-1213 - - FAX 630 406 9472 �/�/�/. kl be ri n c. com LuLu w J w w 0 J w Y � S o Lo W W c co 0 o- QAFF ° m O O Y 0 W a m J O ; ® - AT A B - ANCHOR BOLT ABR -ABRASIVE AT -(1) - ACOUSTIC TILE CEILING (TYPE) - ABOVE FINISH AFG - ABOVE FINISH GRADE ACOUS - ACOUSTIC ADD'N - ADDITION ADD'L - ADDITIONAL ADJ - ADJACENT ADJT - ADJUSTABLE AL -ALUMINUM ALT - ALTERNATE EXP -EXPANSION EXP CONST - EXPOSED CONSTRUCTION FD -FLOOR DRAIN FDN - FOUNDATION FE - FIRE EXTINGUISHER FEC - FIRE EXTINGUISHER CABINET FHC - FIRE HOSE CABINET FIN - FINISH FLR - FLOOR FRT - FIRE RETARDANT TREATED (RATED) FUR CHN L - FURRING CHANNEL FTG -FOOTING GA - GAUGE PL -PLATE PL LAM - PLASTIC LAMINATE PL , -PLASTER PLB G - PLUMBING PLBYWDCONTR _ PLYWOOD - PLUMBING CONTRACTOR PNT - PAINT PVC - POLYVINYL CHLORIDE PL -(1) - GYPSUM PLASTER (TYPE) R OR RAD - RADIUS R - RISER RD -ROOF DRAIN RO - ROUGH OPENING .A . °. a` :. CONCRETE BRICK MASONRY IN PLAN CONCRETE MASONRY IN PLAN (RUNNING BOND) CONCRETE MASONRY IN PLAN (STACK BOND) ANCH - ANCHOR AP - ACCESS PANEL APPROX - APPROXIMATE GALV - GALVANIZED GEN CONTR - GENERAL CONTRACTOR GC - GENERAL CONTRACTOR RF (1) - RUBBER FLOORING (TYPE) RH - RIGHT HAND REF - REFERANCE Z ASPH AUTO AVG BSMT BD - ASPHALT - AUTOMATIC - AVERAGE - BASEMENT - BOARD GL - GLASS GYP DB -1 - GYPSUM WALL BOARD (DRYWALL)(TYPE) GYP PL- 1 - GYPSUM PLASTER (TYPE) H - HIGH HD - HEAVY DUTY REINF - REQ'D - RM - SF - SI - REINFORCING REQUIRED ROOM SQUARE FOOT SQUARE INCH w STONE MASONRY IN PLAN RAKED JOINT IN PLAN CTRL./EXP. JOINT IN PLAN BITUM BLDG BLK'G BM - BITUMINOUS/BITUMASTIC - BUILDING - BLOCKING (WOOD) - BEAM HD - HARD HDNR - HARDENER HD WD -(1) - HARD WOOD (TYPE) HDWRE - HARDWARE SK - SS - SSK - SQ - SINK STAINLESS STEEL SERVICE SINK SQUARE Z w BRICK MASONRY IN SECTION DETAIL B. M. - BENCH MARK BT STL PL - BENT STEEL PLATE BRG - BEARING HGT - HEIGHT HM - HOLLOW METAL HP - HIGH POINT SCHED - SCHEDULE SEAL/HDNR - SEALER/HARDENER SEC - SECTION Z w BRKBRKT BTM BTW'N CJ CAB CEM PL- CT PAV-�13 CIPC CLG CLR CO CMU COL COMB COMP - BRICK KET -BOTTOM - BETWEEN - CONSTRUCTION/CONTRACTION JOINT -CABINET 1 - CEMENT PLASTER (TYPE) - CERAMIC PAVER TILE (TYPE) - CAST- IN- PLACE CONCRETE - CEILING - CLEAR - CLEAN OUT - CONCRETE MASONRY UNIT - COLUMN - COMBINATION - COMPRESSIBLE HOG IZ - HEATING HORIZONTAL S HVAC -HEATING/VENTILATING/AIR CONDITIONING IN - INCH ID - INSIDE DIAMETER INCL -INCLUDE (D) INSUL - INSULATION OR INSULATING JT - JOINT KD - KNOCK DOWN L - LONG LAM - LAMINATED LAV - LAVATORY LH - LEFT HAND LP - LOW POINT LGT WGT - LIGHTWEIGHT LL - LIVE LOAD SHT M - SOG -SLAB SPEC - SPC'G - SPK'R -SPEAKER STN - STD- STD WGT - STL - STRUCT - SUSP - SYM - T - T&G - T/B - SHEET SIMILAR ON GRADE SPECIFICATION(S) SPACING STN STANDARD STANDARD WEIGHT STEEL STRUCTURAL OR STRUCTURE SUSPEND(ED) SYMMETRICAL TREAD TONGUE AND GROOVE TOP OF BEAM BUILDING CODE DATA w O w J M CONCRETE MASONRY IN SECTION DETAIL 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL MECHANICAL CODE 2014 ILLINOIS STATE PLUMBING CODE 2014 NATIONAL ELECTRIC CODE 2015 INTERNATIONAL PROPERTY MAINTENANCE CODE 2015 INTERNATIONAL EXISTING BUILDING CODE 2015 INTERNATIONAL FUEL GAS CODE 2015 INTERNATIONAL ENERGY CONSERVATION CODE ILLINOIS ACCESSIBILITY CODE - CURRENT EDITION LOCAL AMENDMENTS TO THE ABOVE CODES i i� i STONE MASONRY IN SECTION DETAIL STEEL IN SECTION DETAIL DISCONTINUOUS WOOD BLOCKING IN SECTION COMPT, D - COMPACTED LLH - LONG LEG HORIZONTAL T/C - TOP OF CURB CONC CONC OPNG COND - CONCRETE - CONCRETE OPENING - CONDITION LLV - LONG LEG VERTICAL LVR - LOUVER MO - MASONRY OPENING T/F - T/S - T/STL - TOP OF FOUNDATION TOP OF SLAB TOP OF STEEL CONTINUOUS WOOD BLOCKING IN SECTION CONT - CONTINUOUS MT - METAL THRESHOLD T/W - TOP OF WALL CONTR C1) CT -(1) - CONTRACT (OR) -CARPET (TYPE) - CERAMIC TILE (TYPE) MAS'Y - MASONRY MAT'L -MATERIAL MAX - MAXIMUM TB (4) - TOM -TOP TYP - TACKBOARD (LENGTH) OF MASONRY TYPICAL o FINISHED WOOD INPT- SECTION DETAIL CTR - COUNTER MB -(16) - MARKERBOARD- (LENGTH) UNO - UNLESS NOTED OTHERWISE CTR SK CTS CUH CUV DIA DIM DN DR DWG'S DTL DWL'S -COUNTER SINK - CENTER(S) - CABINET UNIT HEATER - CABINET UNIT VENTILATOR - DIAMETER - DIMENSION - DOWN - DOOR - DRAWINGS - DETAIL - DOWELS MECH -MECHANICAL MECH CONTR - MECHANICAL CONTRACTOR MFR - MANUFACTURER MIN - MINIMUM MISC - MISCELLANEOUS MSB - MOP SERVICE BASIN (SINK) MT(D) - MOUNT(ED) MTL - METAL NIC - NOT IN CONTRACT NOM - NOMINAL NTS - NOT TO SCALE VBC -VINYL VBS - VCT - VEN PL (1) - VERT - W - W/ - W/0 - WCG - WD - WDN - BASE COVED VINYL BASE STRAIGHT VINYL COMPOSITION TILE VENEER PLASTER (TYPE) VERTICAL WIDE OR WIDTH WITH WITHOUT WALL CORNER GUARD WOOD WINDOW RIGID BOARD INSULATION SEALS &CERTIFICATES o W y w o m RIGID BOARD INSULATION (ROOFING) ARCHITECT'S MECHANICAL ENGINEER'S ELECTRICAL ENGINEER'S SEAL SEAL SEAL I HAVE PREPARED, OR CAUSED TO BE PREPARED UNDER MY DIRECT SUPERVISION, THE ATTACHED PLANS BATT INSULATION EA - EACH NO - NUMBER WGT - WEIGHT AND SPECIFICATIONS AND STATE EJ - EXPANSION JOINT OA - OVERALL WP - WATER PROOF THAT TO THE BEST OF MY EL - ELEVATION ELEC - ELECTRIC/ELECTRICAL ELEC CONTR - ELECTRICAL CONTRACTOR ELEV - ELEVATOR EMBED - EMBEDMENT EMER - EMERGENCY EP PNT - EPDXY PAINT EQ - EQUAL EW - EACH WAY EWC - ELECTRIC WATER COOLER EWH - ELECTRIC WATER HEATER ER -(26) - EXHIBIT RAIL (LENGTH) EXIST — EXISTING OC - ON CENTER OD - OUTSIDE DIAMETER OF - OUTSIDE FACE OPN G - OPENING OPP - OPPOSITE OPP HD - OPPOSITE HAND PSF - POUNDS PER SQUARE FOOT PSI - POUNDS PER SQUARE INCH PT - PRESSURE TREATED PTN, - PARTITION PAV T - PAVEMENT PC - PIECE PFM — PERMANENT FLOOR MAT WWF - WSB - WELDED WIRE FABRIC WALL SERVICE BASIN GYPSUM BOARD KNOWLEDGE AND BELIEF, AND TO THE EXTENT OF MY CONTRACTUAL OBLIGATION, THEY ARE IN COMPLIANCE WITH IBC 2009 EDITION, THE ENVIRONMENTAL BARRIERS ACT AND THE ILLINOIS ACCESSIBILITY CODE. KLUBER, INC. ILLINOIS PROFESSIONAL DESIGN FIRM LICENSE #184-001284 JOB NO. DRAWN CHECKED APPROVED 17-210-1103 CJH CJH CJH ACOUSTICAL CEILING PANEL SHEET TITLE BITUMINOUS CONCRETE IN SECTION PAVING COVER GENERAL SYMBOLS DRAWING SHEET, NOTES, AND INDEX o o�o o�o o� �p Ngo AGGREGATE BALLAST, FILL OR BACKFILL IN SECTION SHEET NUMBER THE MATERIALS, ABBREVIATIONS, AND DRAFTING SYMBOLS LEGEND ARE EACH AN ALL INCLUSIVE MASTER LIST USED BY THIS FIRM. THE INCLUSION OF THESE LEGENDS THESE DOCUMENTS DOES NOT IMPLY THAT ALL THE SYMBOLS OR MATERIALS INCLUDED INTO IN THESE "G" SERIES "G" SERIES "G" SERIES "A" SERIES "MEP" SERIES "MEP" SERIES Gl 00 UNDISTURBED EARTH LEGENDS ARE INCORPORATED INTO THIS PROJECT. EARTH BACKFILL 0 CO 00 M 0 00 0 N LO Copyright © 2017 KLUBER, INC. 12" 3'-0" MIN. CONTROL i AREA � 5'-0" MIN. � / • O i o i 3'-0" MIN. - i i 17' � 12" 41 I I I I � L-------� c r 4'-0" MIN. I (CLEAR "' oo V-160 „ FLOOR SPACE — LCLEAR FLOOR SPACE INTERMEDIATE GUARD • SPACING TO NOT ALLOW FRONT AND SIDE APPROACH PASSAGE OFA 4" SPHERE z 1'-6" rCONTROL 4'-8" MIN. W/ WALL MOUNTED W.C. w Z W 0 N NOTE: SAME HEIGHT GUARD AND O r co 0 M E (? AREA L = W 0° U) z HANDRAILS IS NOT N 'o - o M 4'-11" MIN. W/ FLR. MOUNTED W.C. Q m w N — — ALLOWED. o M of o I Z 'CO C c6 �o 6 .0tY N t STALL AT END OF ROW o o� 1,_0„ C a T + 12" T F N 4' 0" MIN. _ ¢ 1 EXTNSN TREAD ` 1 MIN. '_ " ,°_ °� o ® WALL DEPTH c_> rr w RAIL N I 1" THE CLEAR SPACE ° a Z I a L— 711 x RISER a BETWEEN THE HANDRAILcn AND WALL OR OTHER SURFACE TO BE 1-1/2" Z HANDRAIL EXTENSIONS 1 O TRANSFER SHOWER � N.T.S. N.T.S. HEIGHT 11"MIN. HANDRAILS SHALL RETU00 RN O TO A WALL, GUARD, Il., Ilk TREAD WALKING SURFACE, OR DEPTH BE CONTINUOUS TO �I CLEAR FLOOR SPACE THE HANDRASHALL IL n 4 -0 MIN. — — — — — — ADJACENT STAIR FLIGHT. ALTERNATE DOOR LOCATION O 0 1'-7" MAX. SIDE APPROACH Z — — — — — — - 4" MAX. 2'-8" MIN. uj CLEAR FLOOR SPACE TY P. STAIR INFORMATION 4 0' MIN. a l 1 z cp 2 N I CLEAR FLOOR SPACE) — " ,�_ , Z a (RAMP INFORMATION SIMILAR) N.T.S. 1 — 1'-5" MIN. oo O N T o O in O L — M LL �Z 6 a S-536" MIN. X � LATCH APPROACH 1'-0" MAX CONTROL MOUNTING HEIGHTS �w » , » ONLY, OTHER 3-3 TO 3-5 W 40 APPROACHES 4'-0" MIN. 4'-4" MIN. INSULATE DRAIN PIPES TO PREVENT CONTACT Q X J CLEAR FLOOR SPACE, 4'-8" MIN. W WALL MOUNTED W.C. / a 4'-11" MIN. W/ FLR. MOUNTED W.C. N' N N I' STANDARD STALL Y W `V O O n „ 6 MAX. 8 MIN. O 1 m M 1'-5" MIN. FRONT APPROACH Q YO W 3'-3" TO 3'-5" 3'-3" TO 3'-5" 0� 300 "°°° a0 m ELEVATOR 12 THRESHOLDS 9 LAVATORY 6 N.T.S. N.T.S. N.T.S. � O Q Y 3'-6" MIN. x N J r O 1'-0" MA 1'-0" MAX 3'-6" MIN. > 4'-0" MIN. 40 3- W _ o I O I 0 0 0 0 n M M Lu 1 -0 MAX r 7 z ® TOILET PAPER N DISPENSER r, o TOILET PAPER N - x DISPENSER I o SRC 100 O I I ® c1 MOUNTING HEIGHTS o MOUNTING HEIGHTS o N CLEAR FLOOR SPACE in j- in I I- z W Z W 3'-0" MIN. W x CD �- 3'-0" MIN. W 0 � 1'-5" TO 1'-7" z O oO 40 ih 0 M p x x OO a, O a, c ZZ e o o I CV o o CV LuO CV MOUNTING HEIGHTS MOUNTING HEIGHTS 6" MAX. 8" MIN. FIRE EXT. CABINETS 11 INTERIOR SIGNAGE 8 DRINKING FOUNTAIN 5 SINGLE -USER TOILET ROOM 4 MULTI-USER TOILET ROOM 3 GENERAL NOTES N.T.S. N.T.S. N.T.S. N.T.S. N.T.S. co H G W — — — — — — — - ---- - C o r No I I I I I I o I N o ' z� 0 4'-6" of z 3 3'-0" MIN. x "' 4'-0" MIN. of z IF X=5'-0" I z I n I ;� 2'-0" 3'-6" MIN. I I V-6" I o 2 -0 1 IF X=4'-6" I a o I JOB NO. 17-210-1103 E - - O of N L. 1'-0" DRAWN CJH IF DOOR HAS CLOSER CHECKED CJH F C) I I AND LATCH I APPROVED CJH SHEET TITLE ACCESSIBILITY REQUIREMENTS L — — — — — — I — J 0."oo'� 4'-0" MIN. SHEET NUMBER PARALLEL DOORS G2012 DOOR CLEARANCES N.T.S. Copyright © 2017 KLUBER, INC. KEYNOTES ARE TYPICALLY NOT DUPLICATED WITHIN A GIVEN DETAIL. KEYNOTES AN UN -KEYNOTED ITEM IN A DETAIL IS THE SAME AS A KEYNOTED ITEM HAVING THE SAME APPEARANCE WITHIN THE SAME DETAIL. 1.000 KEYNOTES TYPICALLY ARE NOT DUPLICATED WITHIN A GIVEN DETAIL. CONTRACTOR IS TO ASSUME THAT AN UN -KEYED ITEM IS TO BE THE SAME AS THE KEYNOTED ITEM WITHIN THE SAME DETAIL. 2.412 DEMOLISH EXISTING SUBSTRUCTURE: CONCRETE SLAB -ON -GRADE; SAW CUT SLAB AT LIMITS OF DEMOLISHED AREA. 2.457 DEMOLISH EXISTING INTERIOR DOOR HARDWARE COMPONENT: DOOR CLOSER. FURNISH AND INSTALL NEW PARALLEL ARM DOOR CLOSER TO MATCH EXISTING FINISH. 2.461 DEMOLISH EXISTING INTERIOR SPECIALTY: TOILET PARTITION. T 2.464 DEMOLISH EXISTING INTERIOR SPECIALTY: TOILET ACCESSORY; AS INDICATED. _ 2.470 DEMOLISH EXISTING INTERIOR WALL FINISH: CERAMIC TILE, BACKER BOARD, GYPSUM BOARD BACK TO EXISTING WALL FRAMING. 2.471 DEMOLISH EXISTING INTERIOR WALL FINISH: CERAMIC TILE. 2.474 DEMOLISH EXISTING INTERIOR FLOOR FINISH: CERAMIC TILE. _ 2.481 DEMOLISH EXISTING INTERIOR CEILING FINISH: DRYWALL AND SUSPENDED FURRING. � 2.484 DEMOLISH EXISTING INTERIOR CEILING FINISH: ACOUSTICAL PANELS AND SUSPENDED GRID. 2.492 DEMOLISH EXISTING MECHANICAL SYSTEM COMPONENT: CEILING DIFFUSER/GRILLE. 2.494 DEMOLISH EXISTING FIRE PROTECTION SYSTEM COMPONENT SCHEDULED FOR RELOCATION: SPRINKLER HEAD. 26.001 �i 26.001 23.370 6 lc /c�c �4 23.370 26.001 L008 L009 v 1.130 ,�al 26. 01 lb 9.511-----,_:_-__:_-------+L==-= 21.1 0 26.001 �� 9.510 04 � � 9.510 21.13 �G------------------1 21 1 0 26.001 9.511 2.484 2 498 TYP. 2.494 2.484 2.492 2.488 nP 2.492 �� � ..• :.: •�,+ yi -------+i Ir- • • - " rs 1 :: 1 1 rz :r� �14 2.494 =="----; �' 2.494 1� I I I I !l I Y •. ... - ;- --- ; •. , , ;�.;: 2.481 1 1• ,� 1 , .:.�� ' ==-=' .. 1 a• '• • % " " I • • •. � __ -*-----i I' I' .• ���� III h II ; 1. 2.498 -------• 2.494 ; II 1 1 ' '• n 1 I 1 I 1 ;. v. •. 11 4_J ------- -11 ------- J -------- _----0 J -+"---�----------------�--- TYPICAL IN ROOM. 2.496 DEMOLISH EXISTING PLUMBING FIXTURE: AS INDICATED. 2.498 DEMOLISH EXISTING LIGHT FIXTURE; REFER TO ELECTRICAL DRAWINGS. 2.499 SALVAGE EXISTING PLUMBING FIXTURE: LAUNDRY TUB. REMOVE TO ALLOW FOR FLOOR CUTTING AND RE -INSTALL AFTER NEW PLUMBING CONNECTION HAS BEEN MADE. 3.032 CAST -IN-PLACE SLAB -ON -GRADE INFILL; DOWELING INTO EXISTING ADJACENT SLAB AND CAST IN PLACE CONCRETE• 4 L• INSTALL W.W.F AS SPECIFIED. 4.402 CONCRETE BLOCK MASONRY: PATCH EXISTING CMU WALL AT LOCATION OF REMOVED TOILET ACCESSORY. 6.461 CASEWORK ACCESSORY: RAAKS METAL COUNTER TOP SUPPORT BRACKET. REFER TO SPECIFICATIONS. 8.721 DOOR CLOSER: FURNISH AND INSTALL LCN OR EQUAL, 4000 SERIES PARALLEL ARM DOOR CLOSER. THRU BOLT THROUGH EXISTING WOOD DOOR. PATCH HOLES IN WOOD DOOR FROM OLD CLOSER. MATCH EXISTING DOOR HARDWARE COLOR. PROVIDE 5 8 THICK MOISTURE RESISTANT GYPSUM BOARD AND CERAMIC WALL TIL D• 9 303 WITH BACKER BOAR C E C , FULL WALL HEIGHT; REFER TO INTERIOR ELEVATIONS AND ROOM FINISH SCHEDULE. 9.315 CERAMIC FLOOR TILE. 9.510 ACOUSTICAL CEILING PANELS AND GRID. 9.511 ACOUSTICAL CEILING ACCESSORY: PAINTED METAL EDGE TRIM; 12" HIGH. REFER TO SPECIFICATIONS. 10.213 METAL TOILET COMPARTMENT: CONFIGURATION AS INDICATED. o o co ci D IN i o - o 00 o ro v C3 E co - co Z 0 to c 12.365 COUNTERTOP: SOLID SURFACING; 1-1/4" EDGE THICKNESS, U.N.O. 12.368 COUNTERTOP: SOLID SURFACED SINK BOWL TO MATCH EXISTING. REFER TO SPECIFICATIONS. W n/ CEILING SYMBOL LEGEND 21.130 SPRINKLER PIPING/FITTING/HEAD TO BE RELOCATED TO NEW CEILING LOCATION -CENTER OF TILE. 23.370 MECHANICAL DIFFUSER/GRILLE: REFER TO MECHANICAL DRAWINGS. 0 SYMBOL DESCRIPTION SYMBOL DESCRIPTION GYPSUM BOARD FLOURESCENT LIGHT FIXTURE . 24" X 48" ALL EXISTING SPRINKLER HEADS TO BE RELOCATED IN LOCATIONS SHOWN. ALL SPRINKLER HEADS SHALL BE CENTERED ON CEILING TILE. ALL EXISTING DRYWALL AND ACOUSTICAL CEILINGS SURFACES, LIGHTING AND SUPPORT FRAMING TO BE REMOVED IN ITS ENTIRETY IN BOTH TOILET ROOMS. TYPICAL. 26.001 LIGHT FIXTURE: REFER TO ELECTRICAL DRAWINGS. 0 FLOURESCENT LIGHT FIXTURE 12" X 48" �r . • PLASTER ~� FLOURESCENT LIGHT FIXTURE STRIP uj E ❑ LIGHT FIXTURES 24"X24" FLOUR.; 12"X12" INCAN. NORTH NORTH ACOUSTICAL CEILING TILE : 12 x 12 SPECULAR CEILING GRID : 1" X 1" WITH FLOR. LGTS. W d 0 0 o A B C D DOWN LIGHT FIXTURES : A: SPOT B: DOWN C: WALL WASHER D: SCONCE uj J W � O YO Q N 00, pip Y Y 0 J O u- m °Yw 0 ° Y J N Q J 0 > r ACOUSTICAL CEILING TILE : 24"X24" ® EXIT LIGHT FIXTURE LIGHT TRACK FIXTURE =124" ACOUSTICAL CEILING TILE : X 48" EMERGENCY LIGHT FIXTURE GENERAL NOTES REFLECTED CEILING PLAN 1' SCALE: 1/4" = -0" DEMOLITION REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0" �y ® SPRINKLER HEAD 1. REFER TO DRAWING G100 FOR PROJECT GENERAL NOTES. 2. ALL EXISTING CERAMIC TILE SURFACES SHALL BE REMOVED FROM EACH TOILET ROOM. ACCESS PANEL: 24" X 24" : U.O.N. ® MECHANICAL DIFFUSER : SUPPLY ® MECHANICAL DIFFUSER RETURN 3. ALL EXISTING GYPSUM BOARD SHALL BE REMOVED IN ITS ENTIRETY THROUGHOUT BOTH TOLIET ROOMS AND SHALL BE REPLACED WITH J" THICK MOISTURE RESISTANT GYPSUMBOARD FOR FULL HEIGHT OF WALL SURFACES PRIOR TO NEW CERAMIC TILE INSTALLATION. TYPICAL. 4. EXPOSED BRICK MASONRY SURFACES AT WOMENS TOILET ROOM L008 AT SOUTH WALL SHALL BE SURFACED WITH W Z EXPOSED METAL THICK MOISTURE RESISTANT DRYWALL BY LAMINATING TO THE BRICK MASONRY SURFACES WITH CONSTRUCTION ADHESIVE PRIOR TO CERAMIC TILE INSTALLATION. TYPICAL. uj TOILET ACCESSORY SCHEDULE 5. IN STUD/GYPSUM BOARD PARTITIONS AND WALLS, PROVIDE 2X FIRE RETARDANT TREATED WOOD BLOCKING FOR WALL -MOUNTED ITEMS REQUIRING MECHANICAL ANCHORAGE. 6. SPOT ELEVATIONS ARE DESIGNATED NOMINAL HEIGHTS ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. COORDINATE FINAL HEIGHTS OF CEILING ELEMENTS WITH INFORMATION CONTAINED ON STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL DRAWINGS. W MARK DESCRIPTION CAT. NO. REMARKS MOUNTING HEIGHTS 7. PROVIDE ARMSTRONG AXIUM TRIM AT CHANGES IN ACOUSTICAL CEILING HEIGHTS. REFER TO SPECIFICATIONS. 8. PATCH ALL EXISTING DRYWALL SURFACES TO MATCH EXISTING FROM DEMOLITION AND NEW CONSTRUCTION, 2 ❑A S.S. GRAB BAR - 36" 812-36 SNAP-ON FLANGE COVER SEE SHEET G201 ❑6 S.S. GRAB BAR - 42" 812-42 SNAP-ON FLANGE COVER SEE SHEET G201 5-2" 4'-8" 2'-1Y" 5'-3" 12.365 9.303 10.213 4.402 J C A 2.464 2.471 2.464 COORDINATE WITH DEMOLITION DRAWINGS. 9. EXISTING WALL STUDS WILL NEED TO BE MODIFIED TO ACCOMMODATE NEW TOILET ACCESSORY LOCATIONS. MOUNTING HEIGHTS SHALL BE PER A.D.A. AND AS SHOWN ON SHEET G201. 10. ALL EXISTING WALL MOUNTED ELECTRICAL DEVICES SHALL BE REMOVED AND EXTENSION RINGS INSTALLED ON EXISTING JUNCTION BOXES PRIOR TO NEW DRYWALL BEING INSTALLED. COORDINATE EXISTING JUNCTION BOX LOCATIONS WITH THE LAYOUT OF NEW TOILET ACCESSORIES. RELOCATE ELECTRICAL JUNCTION BOXES PRIOR TO RE-DRYWALLING. INSTALL NEW ELECTRICAL SWITCHES, OUTLETS, ETC. ALONG WITH NEW COVER PLATES. TYPICAL. w uj> 0 a S.S. GRAB BAR - 18" (VERTICAL) 812-18 SNAP-ON FLANGE COVER SEE SHEET G201 a WALL MOUNTED SOAP DISPENSER 5001 -SS SURFACE MOUNTED 48" MAX. TO DISPENSER F CHANNEL FRAME MIRROR 781-2436 24" X 36" 40" TO MAXIMUM BOTTOM 12.368 r=Lj2.496 F - B °O� 0 1 oO _ 6.461 L008 J G o o L009 2.499 0 o � � 0 i D - _ ;r, �, 12.368 C ° B 3.032 o ,� � �.`' >; J G '� i C14 7`� 12.365 10.213 8 '�' ` 12.368 �, ' a'.:...' 4 �0 • , • 3 A900 1 N 0 F 2 -3 6 D ®10 2 6.461 X = _ - i 9.315 F "' 12. j368 L008.1� T L-- J 9.315 9.303 8 7212.457 FURR OUT 5" 4'-9" 5'-3Y" 3'-315/,6' 5'-5Y6" WITH 3-5/8" Ir 511 MTL. STUDS 5" 10" AND 5/8" GYP. TO CONCEAL PLUMBING PIPING 2.470 2.412 2.496 2.464 2.470 2.474 TYP. WHOLE ROOM 1--tJ F=-==------�-__------__- 1 1-____�_,- ___- 2.471 2.461 ( c ;; IU 2.470 11Y - _:: _ ��� ;;I 1;; 2.496 =--- o,~`O- 2.4961;; - --- - - - ---,-, ;;, �; a k, ':-s4 ::..,:.:.., . -_ t: - ?'-' • ' .y. _=-- I 2.i7fl ' , =_ 2.412 �"�' 4•'.• ,.` � � 496 __ I ;'�2.496 ��I :J „--_ _„ 1 .-. 1 2 471 :', ±;,- �.F.:_; -- 1 1 A 2.471 2.461 �__=====r=T=====__� r-===--_' ;I 2.464 x 1 2.461 - 1 ' _.' •...', 2.��6 ",.-- -� �'��. ______ ; �;;_�`'_ I! %�" 2.496 ,. =�a 2.496 I 2.471 �_ x•464 _-__- � ;_______� ;�, r� �ti L---------- -------- -----� `a, „y �t"' 1 ' l" 2.471 2.470 ' 2.470 _; r; ,,%' '�a� 2 496 `' ' '"" ' `--- 2.474 2.464 2.470 TYP. WHOLE ROOM r++ G SANITARY NAPKIN DISPOSAL 4781-15 SURFACE MOUNTED 44" TO TOP MAX. ❑J DOUBLE TOILET TISSUE DISPENSER 5241-2 SURFACE MOUNTED SEE SHEET G201 �K AUTOMATIC PAPER TOWEL DISPENSER 68523A SURFACE MOUNTED, BATTERY 48 MAX. TO DISPENSER OPENING ROOM SCHEDULE �L WALL MOUNTED SOAP DISH 0720-Z SURFACE MOUNTED " 48 MAX. TO DISH RIM o Lu cn L cn ~ z w v O 0 2 m ti o �N SQUARE TOWEL BAR 7360-624 CONCEALED MOUNTING 48" MAX. TO TOP OF BAR RM. NO. ROOM NAME RM. NO. ROOM NAME SHOWER CURTAIN ROD 1224 CONCEALED MOUNTING L008 L009 EXISTING WOMEN'S TOILET ROOM , EXISTING MENS TOILET ROOM SHOWER CURTAIN HOOK 1200 SHU VINYL SHOWER CURTAIN 1200 V ANTI -BACTERIAL ANTI -FUNGAL ANTI -MILDEW FLAME RETARDANT ❑T AUTOMATIC PAPERTOWEL OWEL DISPENSER/ WASTE 204692A-6 SEMI -RECESSED 61"VERTO TOM F UF.IT KEY PLAN �U FREESTANDING OPEN WASTE RECEPTACLE 0813 FREE STANDING 13 X 30 X13 FURNISH AND INSTALL NEW �" GYPSUM BOARD OVER EXISTING AND NEW METAL WALL STUDS. AT SOUTH WALL OF ROOM L008 WHERE EXPOSED BRICK MASONRY EXISTS, FURNISH AND INSTALL J" LAMINATED GYPSUM BOARD DRYWALL OVER BRICK ALL EXISTING CERAMIC FLOOR AND WALL TILE TO BE DEMOLISHED IN ITS ENTIRETY. REMOVE ALL EXISTING GYPSUM BOARD DRYWALL IN ROOM. TOILET ACCESSORY GENERAL NOTES JOB NO. 17-210-1103 MASONRY. INSTALL SPECIFIED CERAMIC TILE OVER GYPSUM DRAWN PJT 1. A.S.I. & BRADLEY CATALOG NUMBERS ARE USED FOR REFERENCE ONLY, UNLESS OTHERWISE NOTED. DRYWALL SURFACES. REFER TO SPECIFICATIONS FOR TYPE OF DRYWALL TO BE USED. CHECKED CJH 2. MOUNTING HEIGHTS PER ADA -AG (AMERICAN'S WITH DISABILITIES ACT ACCESSIBILITIES GUIDELINES). APPROVED CJH 3. MOUNTING HEIGHTS ARE FROM FINISHED FLOOR TO HEIGHT INDICATED. SHEET TITLE FLOOR PLANS & REFLECTED CEILING NORTH NORTH PLANS NORTH SHEET NUMBER A31 0 FLOOR PLAN 3 SCALE: 1/4" = 1'-0" DEMOLITION FLOOR PLAN SCALE: 1/4" = 1'-0" ROOM FINISH SCHEDULE WALLS ROOM FLOOR BASE CEILING NO. ROOM NAME NORTH SOUTH EAST WEST REMARKS FIN. CC. FIN. CC. FIN. CC. FIN. CC. FIN. CC. FIN. C. FIN. CC. L008 EXISTING WOMEN'S TOILET ROOM F3 CFTA 1 63 CBTA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA I Cl ACTA 3,5,7,9,10 L009 EXISTING MEN'S TOILET ROOM F3 CFTA I B3 CBTA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA W1 /W3 (P1) CWTA/PA I Cl ACTA 3,5,7,9,10 AREA CODE MANUFACTURER CERAMIC CFTA CROSSVILLE, INC.; WOOD IMPRESSIONS FLOOR PORCELAIN TILE TILE COLOR CODE SCHEDULE COLOR/CAT NO. #AV194-GUNSTOCK; 6" X 18" WOODGRAIN AREA CODE MANUFACTURER SOLID SSA AVONITE SURFACE SSC INTEGRAL LAVATORY SINK BOWLS CERAMIC WALL TILE CWTA AMERICAN OLEAN; RAPPORT; WALL TILE #RP04 HARMONY BEIGE; 12X24 PLASTIC LAMINATE PLA WILSONART CWTB AMERICAN OLEAN; MINI ROMAN MOSAICS WITH STONE; SQUARE PATTERNS COLOR - BEIGE MIX; 4" HIGH ACCENT TILE AS SHOWN ON DRAWINGS F4 RUBBER FLOORING/STAIR TREAD/RISERS co N F5 EPDXY PAINT F6 FOOT GRILLE E F7 CERAMIC BASE TILE CBTA AMERICAN OLEAN; RAPPORT; COVE BASE TILE #P-36C9T; 6"HX12"L; MATCH WALL TILE COLOR PAINT PA SHERWIN WILLIAMS LATEX -"PEARL" P2 PB SHERWIN WILLIAMS PC SHERWIN WILLIAMS WALL WTGA LATICRETE GROUT FLOOR I FTGA I LATICRETE GROUT - MUSHROOM - SANDED GROUT 14: Wills] W_1Ia1101111991>eAlf)3'Allel:Zf111 00]AIIIlk [el W141l:=01100m:1441�y29y1lk/."ma111161 COLOR/CAT NO. COLOR: #K3-8343 PEARL COLOR: #F1-8010 BONE 9K-78 - AMBER CHERRY - PREMIUM SW 6150 - UNIVERSAL KHAKI SW 7048 - URBAN BRONZE SW 7006 - EXTRA WHITE r/,b'�y00:1LTA IIIA1iI(till W1:0 FINISH TYPES AREA I FIN. I DESCRIPTION FLOOR F1 I RESILIENT TILE: 12"X12" F2 CERAMIC TILE: 12"X12" F3 CERAMIC TILE: 6"X18" F4 RUBBER FLOORING/STAIR TREAD/RISERS co N F5 EPDXY PAINT F6 FOOT GRILLE E F7 RESILIENT SHEET BASE B1 I RESILIENT BASE AS SPECIFIED: 4" COVE B2 CERAMIC TILE COVE BASE; 3" X 12" B3 CERAMIC TILE COVE BASE; 6" X 12" WALLS W1 I CERAMIC TILE; 12"X24" W2 SOLID SURFACING PANELS W3 GYPSUM BOARD; 5/8" THICK; MOISTURE RESISTANT W4 CERAMIC TILE; 12"X12" GLASS FG1 1/4" SAFETY GLASS; TEMPERED; CLEAR FG2 1/4" WIRED; CLEAR SG1 1" INSULATED GLASS UNITS, TINTED SG2 1" INSULATED GLASS UNITS, CLEAR SG3 1" INSULATED SPANDREL UNITS C'nnvrinht Ccs gnl7 KI I1RFR INC' AREA I FIN. I DESCRIPTION CEILING C1 ACP: 24"X24" (MTL. SUSP. SYS. SS -1) C2 SUSP. GYP. BD.: %"THK.; MOISTURE RESISTANT; MTL.FRAMING C3 SUSP. GYP. BD.: %"THK.; MTL. FRAMING -TYPE 'X' DRYWALL C4 EXPOSED CONSTRUCTION - FINISHED co N C5 EXPOSED CONSTRUCTION - UNFINISHED C6 NOT USED E C7 CERAMIC TILE C8 ACP: 24"X24" (CLEAN ROOM VL) PAINT P1 LATEX -"PEARL" P2 LATEX - "SEMI -GLOSS" P3 LATEX - "FLAT" P4 ENAMEL - "SEMI -GLOSS" P5 PREFINISHED: REFER TO SPECS. P6 EPDXY - "SEMI -GLOSS" STAIN I S1 I STAIN & FINISH: REFER TO SPECS. FINISH REMARKS 1. EXISTING AND NEW DRYWALL CEILINGS AND SOFFITS (C2 AND C3) TO BE PAINTED P3, COLOR PC. 2. W2 FOR WALLS ABOVE SHOWER BASIN TO 8 FEET HEIGHT, W1 FOR ALL OTHER WALLS IN ROOM; REFER TO PLANS. 3. REPAINT ALL EXISTING METAL DOOR FRAMES IN PROJECT SCOPE P4, COLOR PB. 4. PLASTIC LAMINATE BASE CABINETS TO BE COLOR PLA. 5. TOILET PARTITIONS TO HAVE BAKED ENAMEL FINISH, COLOR ALMOND. 6. TOILET PARTITIONS TO HAVE BAKED ENAMEL FINISH, COLOR TO BE DETERMINED BY OWNER FROM FULL RANGE OF MANUF. STANDARD COLORS. 7. CERAMIC TILE WALL GROUT TO BE COLOR WTGA; CERAMIC TILE FLOOR GROUT TO BE COLOR FTGA. 8. CERAMIC TILE WALL GROUT TO BE COLOR WTGA; CERAMIC TILE FLOOR GROUT TO BE COLOR FTGB. 9. CERAMIC WALL TILE ACCENT BAND, COLOR CWTB. REFER TO INTERIOR ELEVATIONS. 10. SOLID SURFACE COUNTERTOP TO BE COLOR SSA, INTEGRAL BOWLS TO BE COLOR SSC. 11. SOLID SURFACE COUNTERTOP TO BE COLOR SSB, INTEGRAL BOWLS TO BE COLOR SSC. 12. REPAINT ALL EXISTING METAL DOOR FRAMES IN PROJECT SCOPE P4, COLOR TO MATCH EXISTING DOOR FRAME COLOR. 13. CERAMIC FLOOR TILE IN PORTION OF ROOM NEAR LAVATORIES. SEE FLOOR PLAN FOR TILE BREAK POINT. GENERAL NOTES 1. REFER TO A300 SERIES REFLECTED CEILING PLANS FOR CEILING HEIGHTS. 2. REFER TO ROOM FINISH SCHEDULE FOR SPECIFIC DOOR AND FRAME FINISHES. Z O F O Z W O O w F W J W W OaN J 00 m � W Y Y O J W 0 0 m O W Q � O QTY J J Na ��O T Lu H Z W Z W Z w W O W J m cn I— Z JOB NO. 17-210-1103 DRAWN CJH CHECKED CJH APPROVED CJH SHEET TITLE DOOR, FRAME & HARDWARE SCHEDULES TOILET ACCESSORY SCHEDULE SHEET NUMBER ljollill 0 c� V i c_A O co N CD C) S2 O E oo O V U m C =_ CO O=_ ,I- cO E (6 C M O co 0 Z O F O Z W O O w F W J W W OaN J 00 m � W Y Y O J W 0 0 m O W Q � O QTY J J Na ��O T Lu H Z W Z W Z w W O W J m cn I— Z JOB NO. 17-210-1103 DRAWN CJH CHECKED CJH APPROVED CJH SHEET TITLE DOOR, FRAME & HARDWARE SCHEDULES TOILET ACCESSORY SCHEDULE SHEET NUMBER ljollill Copyright © 2017 KLUBER, INC. KEYNOTES 1.000 KEYNOTES TYPICALLY ARE NOT DUPLICATED WITHIN A GIVEN DETAIL. CONTRACTOR IS TO ASSUME THAT AN UN -KEYED ITEM IS TO BE THE SAME AS THE KEYNOTED ITEM WITHIN THE SAME DETAIL. _ 26.001 9.511 9.314 26.001 10.280 10.280 9.313 26.001 9.314 9.311 CERAMIC WALL TILE: COVE BASE. 9.313 CERAMIC WALL TILE: FIELD COLOR. - 9.314 CERAMIC WALL TILE: ACCENT BAND. 0 9.511 ACOUSTICAL CEILING ACCESSORY: PAINTED METAL EDGE TRIM; 12" HIGH. REFER TO SPECIFICATIONS. CD 10.218 TOILET COMPARTMENT. URINAL SCREEN; MATERIAL AS SPECIFIED. C) 10.219 TOILET COMPARTMENT: CONFIGURATION AS INDICATED; MATERIAL AS SPECIFIED. 10.280 TOILET ACCESSORY: TYPE AS INDICATED; REFER TO SCHEDULE. - 10.218 12.365 COUNTERTOP: SOLID SURFACING; 1-1/4" EDGE THICKNESS, U.N.O. _ 12.365 1 000 12.365 12.369 COUNTERTOP SKIRT BOARD: SOLID SURFACING; 3/4" THICK; 5" DEEP. ao T N N 12.369 12.377 COUNTERTOP ACCESSORY: METAL SURFACE MOUNTED COUNTER SUPPORT BRACKET, REFER TO SPECIFICATIONS. 12.369 0 22.400 PLUMBING FIXTURE: REFER TO PLUMBING DRAWINGS. i C14 i N 26.001 LIGHT FIXTURE: REFER TO ELECTRICAL DRAWINGS. o � o o i O 4 0 N O co C 7 - CO(6 C =_ O =_ M O M 10.219 c � 0 22.400 9.313 9.311 9.311 22.400 cn INTERIOR ELEVATION 8 INTERIOR ELEVATION 4 Z SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" O F Q O Z 26.001 9.511 26.001 10.280 9.511 9.314 26.001 10.280 W F CDo CD -A. o O 9.314 � O 10.219 // � �/ � 12.365IEE 00 F 10.218 00 12.369 N i � o W \ � CV J W W OQN J oo�, 9.313 22.400 9.311 9.313 12.377 9.311 1YJ Q O - W 0 Y O INTERIOR ELEVATION INTERIOR ELEVATION SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" O Y O J N Q J _j T W F z W 26.001 10.280 9.314 26.001 9.314 10.280 26.001 i 00o Z 0 10.219 jj o W _ - --------- 10.280 --- - - ----- - -- 0012.365 12.365N ao N W o � o N 12.369 N O 9.313 W J 9.311 10.280 22.400 9.313 12.369 9.311 D INTERIOR ELEVATION 6 1/4" 1'-0" INTERIOR ELEVATION 2 1/4" 1'-0" SCALE: = SCALE: = GENERAL NOTES 1. REFER TO DRAWING G100 FOR PROJECT GENERAL NOTES. 2. REFER TO A300 SERIES REFLECTED CEILING PLAN DRAWINGS FOR CEILING HEIGHTS. cn z 9.314 26.001 9 511 10.280 10.280 10.219 26.001 9.511 9.314 3. COORDINATE CEILING HEIGHTS WITH SECTIONS AND DETAILS. 0 U) w v _ o 10.280 4. COORDINATE LOCATIONS OF WALL -MOUNTED ELECTRICAL ITEMS WITH ARCHITECTURAL ITEMS TO ENSURE NO 0 o OVERLAP. m _ 5. REFER TO FLOOR PLANS FOR TOILET ACCESSORY TYPES AND LOCATIONS. ti 0 of O 6. NOT ALL TOILET ACCESSORIES ARE SHOWN ON THE INTERIOR ELEVATIONS, FOR CLARITY. REFER TO FLOOR PLANS r FOR FULL SCOPE OF TOILET ACCESSORIES. c 4// 0// JOB NO. 17-210-1103 (fl i 12.365 °O 00 O T CV 00 00 DRAWN PJT .n CHECKED CJH 12.369 i 9.311 ROV APPED CJH N SHEET TITLE 10.219 INTERIOR ELEVATIONS 9.313 12.377 9.311 9.313 22.400 10.280 SHEET NUMBER A900 INTERIOR ELEVATION 5 1/4" 1'-0" INTERIOR ELEVATION 1/4" 1'-0" SCALE: = SCALE: = Copyright © 2017 KLUBER, INC. KEYNOTES ARE TYPICALLY NOT DUPLICATED WITHIN A GIVEN DETAIL. KEYNOTES AN UN -KEYNOTED ITEM IN A DETAIL IS THE SAME AS A KEYNOTED ITEM HAVING THE SAME APPEARANCE WITHIN THE SAME DETAIL. 21.100 REMOVE SPRINKLER HEADS AND PROVIDE TEMPORARY CAP FOR NEW SPRINKLER HEAD CONNECTION. 21.200 PROVIDE NEW SPRINKLER HEAD, MATERIAL AND LABOR FOR INSTALLATION IN NEW CEILING CONFIGURATION. _ 22.100 REMOVE PLUMBING FIXTURE. PROVIDE TEMPORARY CAP ON WATER, WASTE AND VENT PIPES. 22.101 REMOVE SINK AS REQUIRED FOR INSTALLATION OF NEW VENT PIPE. 22.102 REMOVE PLUMBING FIXTURE. REMOVE ALL EXPOSED PIPING BACK TO LOCATION OF NEW FURRED OUT WALL. 22.200 PROVIDE NEW PLUMBING FIXTURE. CONNECT TO EXISTING WATER, SANITARY AND VENT PIPING. 22.201 PROVIDE FLOOR DRAIN, WASTE AND VENT PIPES IN RESTROOMS. PROVIDE CONNECTION INTO EXISTING WASTE T AND VENT PIPING. _ 22.202 ROUTE NEW VENT PIPING INTO MECHANICAL ROOM. CONNECT TO EXISTING VENT PIPE. 22.203 NEW PIPES TO BE ROUTED IN FURRED OUT SECTION BEHIND NEW LAVATORIES. 10/10 UP 22.204 RAISE CLEANOUT AS REQUIRED TO MATCH NEW TILE FLOOR SURFACE LEVEL. F T23.100 REMOVE EXHAUST GRILLE. PROVIDE TEMPORARY CAP ON DUCTWORK UNTIL CONNECTION TO NEW GRILLE. AM MECHANICAL ROOM I VENT UP 23.101 REMOVE BRANCH DUCT BACK TO MAIN. PROVIDE PERMANENT CAP ON DUCTWORK. 23.200 PROVIDE NEW EXHAUST GRILLE, ALL LABOR AND MATERIALS TO CONNECT TO EXISTING BRANCH DUCTWORK. I NC 14„ I I 26.200 DEMOLISH EXISTING LIGHT FIXTURE AND DISPOSE ACCORDING TO SPECIFICATIONS. DISCONNECT AND PROTECT o 26.402 I 2" I EXISTING BRANCH CIRCUITRY TO REUSE WITH NEW LIGHT FIXTURES. oQ0 co oro 00 o TYP. 22'2°° - ? - - - - EG -1 26.300 REMOVE EXISTING RECEPTACLE AND REPLACE WITH NEW MATCHING NEMA 5-20R RECEPTACLE WITH GFCI ci N T C3 TYP 23.200 220 CFM I PROTECTION AS SPECIFIED. PROTECT AND REUSE EXISTING BRANCH CIRCUITRY. E 0 E M m 23.200 3" CW 26.400 REMOVE EXISTING SINGLE POLE WALL SWITCH AND REPLACE WITH NEW SINGLE POLE TOGGLE SWITCH AS C6 o 22.201 FD -1 - c - I SPECIFIED. PROTECT AND REUSE EXISTING CIRCUITRY. Y .0 ED 80 L r EG -1 - 26.401 PROVIDE NEW CEILING MOUNTED OCCUPANCY SENSOR (MANUAL ON/AUTOMATIC OFF). EXTEND BRANCH CIRCUITRY _� Y m (D c� -- ° L008 L009 3/4" HW/CW LOOg 220 CFM L009 c - 10/10 AS NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM. DOWN IN FURRED WC -1 26.402 PROVIDE NEW WALL MOUNTED LIGHT FIXTURE AS SPECIFIED. REUSE AND EXTEND EXISTING BRANCH CIRCUITRY - - = 0 OUT SECTION - = LL=1 I WC -1 AND CONTROLS AS NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM. roo. BEHIND WALL o NC4"`a I 419 _ 22 20228.200 DISCONNECT, PROTECT AND REINSTALL EXISTING FIRE ALARM NOTIFICATION APPLIANCE. FD -1 NC O FCO(e) WC -2 0o 2" UFS ® 18/6 UR 2 10/10 " 2 UFS ❑ 0 26.401 2" 22.204 ❑ 0 22.201 I MECHANICAL ROOM z ,� U I O O 26.400 WC -2 O ° UR -1 1 0o p L -1C()) 26.400 __ 22'203 PLUMBING FIXTURE SCHEDULE Q 22.200 l 3/4" HW/CW > V V o)° TYP L-1 °Js - O TAG DESCRIPTION COLD HOT WASTE VENT REMARKS L____J L ----J Z WC -1 WATER CLOSET -FLUSH VALVE 1" - 4" 2" ADAAG COMPLIANT W WC -2 WATER CLOSET -FLUSH VALVE 1" - 4" 2" 26.300 28.200 26.300 21.200 21.200 22.200 TYP UR -1 URINAL -FLUSH VALVE 3/4" - 2" 1-1/2" ADAAG COMPLIANT UR -2 URINAL -FLUSH VALVE 3/4" - 2" 1-1/2" 28.200 TYP TYP L-1 LAVATORY -INTEGRAL TO COUNTER 1/2" 1/2" 1-1/2" 1-1/4" ADAAG COMPLIANT O 1. ALL PLUMBING MATERIALS AND INSTALLATIONS SHALL BE IN STRICT ACCORDANCE WITH ALL STATE AND LOCAL O PLUMBING RULES AND REGULATIONS CURRENTLY IN EFFECT, GOVERNED BY THE ADMINISTRATIVE AUTHORITY HAVING JURISDICTION. 2. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF ALL TRAPS AND CLEANOUTS AS NECESSARY OF THE LOCALITY. 3. THE OPENINGS IN WALLS FOR THE PASSAGE OF PIPES SHALL BE TOTALLY FIRE SEALED TO THE SATISFACTION W OF THE PLUMBING INSPECTOR AND/OR THE AUTHORITY HAVING JURISDICTION. J W NORTH NORTH DIFFUSERS REGISTERS AND GRILLES SCHEDULE > ' Lu O O ac') MARK MODEL SIZE NECK DAMPER MATERIAL REMARKS m a LL Q 0 J EG -1 301 FL 12/6 - OBD AL 1 LV 0 W O Y 0� LU QO ELECTRICAL POWER & LIGHTING PLAN MECHANICAL AND PLUMBING PLAN 1. MODEL BASED ON TITUS. SCALE: 1/4" = V-0" SCALE: 1/4" = 1'-0" O O Y �Na J _j PLUMBING GENERAL NOTES T w W H 1. REFER TO DRAWING G100 FOR PROJECT GENERAL NOTES. z 2. ALL SANITARY, WASTE AND STORM PIPES UP TO AND INCLUDING 3 INCHES SHALL SLOPE AT 1/4 INCH PER W FOOT, 4 INCHES AND LARGER SHALL SLOPE AT 1/8 INCH PER FOOT, UNLESS OTHERWISE NOTED. 3. ALL PIPING IS SHOWN DIAGRAMMATICALLY AND DOES NOT SHOW ALL OFFSETS, DROPS AND RISES. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL MATERIAL AND LABOR FOR A COMPLETE AND WORKING SYSTEM. 4. OBTAIN AND PAY ALL COSTS FOR PERMITS, LICENSES, CERTIFICATE FILING AND INSPECTIONS BY AUTHORITIES Z HAVING JURISDICTION. Lu 5. EXISTING PIPING INDICATED ON THESE PLANS SHALL BE FIELD VERIFIED FOR EXACT LOCATIONS, QUANTITY AND 2 10/10 UPIK PIPE SIZES. - - F T 6. DO NOT CUT THROUGH STRUCTURAL ELEMENTS WHEN INSTALLING OPENINGS REQUIRED FOR ALL DUCTWORK, PIPING, CONDUITS OR OTHER WORK. CONTRACTOR CUTTING THROUGH OR OTHERWISE DAMAGING THESE ELEMENTS WILL BE I VENT UP RESPONSIBLE FOR ALL ASSOCIATED ENGINEERING FEES AND SUBSEQUENT RETRO-FIT/REINFORCING DEEMED MECHANICAL ROOM NECESSARY TO REINSTATE THE CONTINUITY OF THE DISRUPTED ELEMENTS. W > 14„ 7. COORDINATE ROUGH -INS FOR AND INSTALLATION OF PLUMBING FIXTURES WITH ACCESSIBILITY AND MOUNTING INFORMATION CONTAINED ON ARCHITECTURAL DRAWINGS. O 26.200 26.200 i 22.100 2„ I 8. COORDINATE LOCATIONS OF ROUGH -INS FOR SINKS WITH CASEWORK ELEVATIONS CONTAINED ON ARCHITECTURAL TYP. TYP. 23.101 23.100 23.100 DRAWINGS. V 22,10° __` _ 3" CW 9. DRAINAGE AND VENT SYSTEM SHALL BE PRESSURE TESTED WITH WATER OR AIR. l _t F _--__- �r-- -- -, ,--_ J A� I _T -T- ___� c �•=_-;, ;.<; l-_ , TYP _ _ C-3 , I - „ -- -- --- , _; _ - -R - �`,Lu _ I 22.101 I 1- 1 11 11 „ �AV,- I '' 1 1 111 3/4" HW/CW 11 �Jl _ 111 1 ' ', i SI iii lie 1 ,,, ♦ - ♦ - :t.♦ EG . 111 DOWN IN FURRED 1 j I N.4 11I 111 WC I I 1 11 , •=S 10/10 a = -,��al L; i ; OUT SECTION WC BEHIND WALL AV ;; :;._ ' ' 4„ -_ ♦ - 111 ` : � 111 CDco 1M 11 I ♦- - J---- "♦1 I II 1 " Y 11--_ __ 1 I `-�---- i ♦ . - -- �s_„_, „ ♦♦♦°--z,_,;1;�'; bill '' �, i� 11 .'ii 26.200 _L__.--------------- ~- � $ 6------------ --jf= �,- 8 6 -j - UR '` jj 10/10 li _ _ _�1 11 1 TYP.IN L -L-- `----------------a����.___S�1 11 MECHANICAL ROOM �. ROOM SCHEDULE I •: '� ♦' �' � ° % � $ - r--- i� II "-" , ` - " I. �,1 26.400 I F-� I �__ I i; :_� ., ♦'♦, WC ,� -° 1 � ------- �,' ♦'===- � 1�,1 UR �-�' LAV �_ ,♦ ` --_--� ---- -� : " �I-'�� -----------_ L� -___,--- I 1 •1 �'' "•'-'�' RM. N0. ROOM NAME RM. N0. ROOM NAME L008 EXISTING WOMEN'S TOILET ROOM 26.400 ' ' IN 1 ii ^>^ I I II 3/4" HW/CW L009 EXISTING MEN'S TOILET ROOM 1 M 11 I Ilf R N ii , M II LAV , I Ilf I°,1 �♦ ��� V1 V I N 1 �� 1' I ���- Z 22.102 0 Lu Lu 26.300 28.200 26.300 21'100 21.100 TYP TYP Ln Ln 0 o 0 28.200 2 m ti T KEY PLAN Q 0 JOB NO. 17-210-1103 DRAWN BWG/ATR CHECKED DDW/MTK APPROVED DDW/MTK SHEET TITLE MECHANICAL, EJ NORTH NORTH ELECTRICAL AND PLUMBING FLOOR PLANS, SCHEDULES AND DETAILS SHEET NUMBER NORTH MEP31 0 ELECTRICAL DEMOLITION PLAN 4 1/4" 1'-0" MECHANICAL AND PLUMBING DEMOLITION PLAN 2 1/4" 1'-0" SCALE: = SCALE: =