S-1601 - 04/28/2020 - VARIATION - Ordinances (2) ITEM 6.C.1
VILLAGE OF BOARD OF TRUSTEES MEETING
SAUEL E. DEANOAK B R� , K BUTLER GOVERNMEONT CENTOER
1200 OAK BROOK ROAD
OAK BROOK, ILLINOIS
630-368-5000
AGENDA ITEM
Regular Board of Trustees Meeting
of
April 28, 2020
SUBJECT: 1315 and 1425 Kensington Road, Oak Brook Park District — Height
Variation for Sport Field Lighting
FROM: Tony Budzikowski, AICP, Development Services Director
BUDGET SOURCE/BUDGET IMPACT: NA
RECOMMENDED MOTION: I move to approve Ordinance S-1601, which
approves the height variation to Section 13-5-4.1) of the zoning regulations to permit
and allow six (6), 80' high light poles on ball fields 1 and 2 at Central Park North.
Background/History:
At the April 14, 2020 meeting,the Village Attorney was directed to prepare the necessary
ordinance granting approval of a height variation to Section 13-5-4.1) of the zoning
regulations to permit and allow six (6), 80' high light poles on ball fields 1 and 2 at
Central Park North. A copy of the ordinance has been provided for review and reference
purposes.
Recommendation
Approve Ordinance S-1601.
REG BOT 042820 Agenda Item 6.C.1-1315 1425 Kensington-Park DistrVar S-1601 memo.doc RG
Page 1
THE VILLAGE OF OAK BROOK
COOK AND DUPAGE COUNTIES, ILLINOIS
ORDINANCE
NUMBER 2020-ZO-V-EX-S-1601
AN ORDINANCE
GRANTING A VARIATION
TO ALLOW BALL FIELD LIGHTS
FOR PROPERTY COMMONLY REFERRED TO AS
1315 AND 1425 KENSINGTON ROAD
OAK BROOK, ILLINOIS 60523
GOPAL G. LALMALANI, Village President
CHARLOTTE K. PRUSS, Village Clerk
JOHN BAAR
PHILIP CUEVAS
MICHAEL MANZO
MOIN SAIYED
EDWARD TIESENGA
ASIF YUSUF
Village Board
Published in pamphlet form by authority of the
President and the Board of Trustees of the Village of Oak Brook
on this the 28th day of April, 2020
ORDINANCE 2020-ZO-V-EX-S-1601
AN ORDINANCE
GRANTING A VARIANCE
TO ALLOW BALL FIELD LIGHTS
FOR PROPERTY COMMONLY REFERRED TO AS
1315 AND 1425 KENSINGTON ROAD
OAK BROOK,ILLINOIS 60523
PINS:06-26-102-008 and 06-26-102-009
WHEREAS, the Village of Oak Brook (hereinafter referred to as the "Village'l is an Illinois
municipal corporation organized pursuant to the laws of the State of Illinois;
WHEREAS,the Village of Oak Brook is authorized by the Illinois Municipal Code,65 ILCS 5/11-
13-5,to vary its zoning regulations where there are practical difficulties or particular hardship in observing
those regulations for the use,construction,or alteration of buildings or structures or the use of land;
WHEREAS,petitioner has requested a variation from the certain provisions of the Village of Oak
Brook Zoning Ordinance as described herein;
WHEREAS,a petition has been submitted by the Oak Brook Park District,the Property Owner
(hereinafter referred to as the"Owner),of the property located at 1315 and 1425 Kensington Road,Oak
Brook,which is legally described in Exhibit A attached hereto and incorporated herein(hereinafter referred
to as the"Subject Property'l which is zoned CR,Conservation,requesting approval of a variation from
Section 13-5-4D to permit six(6)light poles at a height of eighty feet(80')on the Subject Property in and
around the ball fields to provide for use of said fields during night time sports activities and in order to
provide adequate lighting for the users of said fields owner is requesting certain variations to the Village's
zoning regulations for said purposes as set for the herein(hereinafter referred to as the"Variation'l;
WHEREAS,the Village of Oak Brook Zoning Board of Appeals held a public hearing on March 3,
2020 to consider the petitioner's request and to hear testimony on the proposal and as a result of said
hearing the Village of Oak Brook Zoning Board of Appeals issued a positive recommendation in this matter
all pursuant to proper notice and in compliance with the laws of the State of Illinois and ordinances of the
Village of Oak Brook;
WHEREAS,the Village of Oak Brook Zoning Board of Appeals found the request to be reasonable
in that the requested variation is appropriate under the standards adopted by the Village of Oak Brook in
its Zoning Regulations applicable to zoning variances and made positive findings of fact in support of said
variance;
WHEREAS,the Zoning Board of Appeals recommends approval of the petitioner's request by the
Board of Trustees of the Village of Oak Brook;and
WHEREAS, the corporate authorities of the Village of Oak Brook find that the granting of the
requested variation has no detrimental impact on the health,welfare or safety of the public in general and
finds that the petitioner has met its burden in demonstrating the grounds for the requested variation.
NOW,THEREFORE,BE IT ORDAINED,in open meeting assembled by the Village President and
Board of Trustees of the Village of Oak Brook,Cook and DuPage Counties,Illinois as follows:
Ordinance 2020-ZO-V-EX-S-1601
1315 and 1425 Kensington Road-Variation
PINS:6-26-102-008 and 06-26-102-009
Page 2 of 8
Section 1. Recitals. The Corporate Authorities hereby find that all of the recitals hereinbefore
stated as contained in the preamble to the Ordinance are full,true and correct and do hereby,by reference,
incorporate and make them part of this Ordinance as legislative findings.
Section 2. Grant of Variation. Subject to,and contingent on the conditions,restrictions,and
provisions set forth herein,the Village Board of Trustees shall,and does hereby,approve a Variation to the
Zoning Regulations as follows:
Variation to Section 13-5-413 to allow light poles using LED lights to be increased from 30 to 80 feet in height
on the Subject Property, 1315 and 1425 Kensington Road, Oak Brook, Illinois and legally described in
Exhibit A.
Section 3. Conditions. The approval granted in Section 2 of this Ordinance is expressly
subject to and contingent upon each of the following conditions:
A. Substantial Conformance with Plans. The proposed sports field lights shall be constructed
in substantial conformance to the approved plans as submitted which are attached hereto
and a made a part hereof and as Exhibit B.
B. The field lights shall be LED and controlled by automatic timers,which will only allow use
from dusk to 10:30 p.m.In addition,from December 15 through the last day of February of
each year the lights will be turned off at 9:30 p.m.
C. The field lights will be turned off if there are no activities planned on the fields.
D. Light levels shall comply with the Building Code Amendment 302.15'Maximum Line of
Sight Illuminance at Any Vertical Plane Boundary'and not exceed 0.3 foot-candles along
the west property line and 0.8 foot-candles along the north property line.
E. An as-built photometric plan shall be submitted to the Village after installation of the light
poles.
F. A lighting level survey/verification review to ensure compliance with subsection D shall be
conducted at the second-year anniversary of the light installation and after any significant
change to the light poles,a significant change is considered a modification that will require
a building permit.
G. The applicant shall be required to meet all Village Ordinance requirements at the time of
building permit application as specifically varied or waived.
H. Compliance with Zoning Regulations and Village Code. The Owner shall meet all Village
Ordinance requirements at the time of building permit application except as specifically
varied or waived by this Ordinance.
Section 4. Failure to Comply with Conditions. Upon failure or refusal of the Applicant to
comply with any or all of the conditions,restrictions,or provisions of this Ordinance,the Variation granted
in Section 2 of this Ordinance will, at the sole discretion of the President and Board of Trustees, by
ordinance duly adopted,be revoked and become null and void.
Section 5. Binding Effect. This Ordinance and the privileges, obligations, and provisions
contained herein shall inure solely to the benefit of,and be binding upon the Owner and any and all of its
Ordinance 2020-ZO-V-EX-S-1601
1315 and 1425 Kensington Road-Variation
PINS:6-26-102-008 and 06-26-102-009
Page 3 of 8
heirs,successors,and assigns,and upon any and all current and successor legal or beneficial Owner of
all or any portion of the Property.
Section 6. Effective Date.
A. This ordinance shall be in full force and effect from and after its passage, approval and
publication as provided by law.and
B. The filing by the Owner with the Village Clerk,for recording in the Office of the DuPage County
Recorder of Deeds,of an unconditional agreement and consent("Unconditional Agreement
and Consent'l to accept and abide by each and all of the terms,conditions,and limitations
set forth in this Ordinance.The unconditional agreement and consent must be executed by the
Owner.The unconditional agreement and consent must be substantially in the form attached
hereto and incorporated herein as Exhibit C.In the event that the Owner does not file with the
Village Clerk the unconditional agreement and consent required herein within 60 days after the
date of final passage of this Ordinance,the Board of Trustees will have the right,in their sole
discretion,to declare this Ordinance null and void and of no force or effect.
Section 7. Severability. If any section,paragraph,clause or provision of this Ordinance shall
be held invalid,the invalidity thereof shall not affect any of the other provisions of this Ordinance.
Section 8. Conflict Clause. That all ordinances or parts of ordinances in conflict with the
terms of this ordinance shall be repealed to the extent of said conflict.
Section 9. Publication. This ordinance shall be published in book or pamphlet form as
provided by the Illinois Municipal Code.
Section 10. Recording. This ordinance shall be entered into the minutes and upon the
journals of the Board of Trustees of the Village of Oak Brook.
[Signature page follows]
Ordinance 2020-ZO-V-EX-S-1601
1315 and 1425 Kensington Road-Variation
PINS:6-26-102-008 and 06-26-102-009
Page 4 of 8
1
APPROVED THIS 28th day of April,2020.
Gopal G.Lalmalani
Village President
PASSED THIS 28th day of April,2020.
Ayes: Trustee Bear,Cuevas,Manzo,Saiyed,Tiesenga,Yusuf
Nays: None
Absent: None
G*OF 04R
vQ ego ATTEST:
n
Charlotte K.Pruss
p `?� Village Clerk
C�OO U N T'f ���
Ordinance 2020-ZO-V-EX-S-1601
1315 and 1425 Kensington Road-Variation
PINS: 6-26-102-008 and 06-26-102-009
Page 5 of 8
Exhibit A
Legal Description of Subject Property
Lot 1 in McDonald's Autumn Oaks Subdivision,being a part of Section 26,Township 39 North,Range 11,
East of the Third Principal Meridian,according to the plat thereof recorded June 22,1990 as Document No.
R90-77300 in DuPage County,Illinois.
and
Lot 2 in McDonald's Autumn Oaks Subdivision,being a part of Section 26,Township 39 North,Range 11,
East of the Third Principal Meridian,according to the plat thereof recorded June 22,1990 as Document
No.R90-77300 in DuPage County,Illinois.
1315 Kensington Road: 06-26-102-008(Lot 1)
1425 Kensington Road: 06-26-102-009(Lot 2)
Ordinance 2020-ZO-V-EXS-1601
1315 and 1425 Kensington Road-Variation
PINS:6-26-102-008 and 06-26-102-009
Page 6 of 8
Exhibit B
Plans
Exhibit B
IN
N E KENSNGTON ROAD
a
-
_ 69]' —
--$QL��I I___-_-____ _________I PARCEL LOT LINE
2W'�
281' I T yy LIGHTG3
S9�
-_ 640.
PARCEL LOT LINE
306'
BRIARWGOD 642'I s9+'
362'
I 284' n SS 32
LION �
3 333.
I I I
692'
904•
-- 952'
f
PIN! 06-26-102-009-0000 PIN: 06-26-102-008-0000
i PARCEL LOT LINE
t
s
G
9
I GINGER CREEK
fI} LEGENO
- ♦ IAUSCO LIONT LOCA'ON
W B K^ p.
engineering p'o�FORnT GATORo�p -TRAL PARK NOWT.FIEL05-F.AKI
I ( g W R R RT.Ler�G non�axr LOpRTNW1 w
Datasheet:Light-Structure Systerri
Luminaire and Driver-TLC-LED-1500
r0
Luminaire Data
Weight(luminaire) lb(10 kg)
UL listing number
E338094(pending)
UL listed for USA/Canada
UL1 598 CSA-02.2 Noi
(pending)
_EiDeclaration LM EMC,Rohs
Ingress protection,luminaire IP65
Aluminum,powder-coat
Material and finish
painted
Wind speed rating(aiming only) 150 W(67,
UL,IEC ambient temperature rating, 50°C(122T
luminaire
Photometric characteristics
Projected lumen maintenance per IES TM-21-11
L90(13.5k) -->81,000h
LBO(13.5k) >81,000 h
L70(13.5k) >812ROP-h-
CIE correlated color temperature 5700 K
-color rendering index,(,CRI) 75 typ,70 min
Lumens' 160,000
Footnotes:
1)Incorporates appropriate dirt depreciation factor for life of luminaire.
All components from foundation to poletop are designed
to work together in Light-Structure System-to ensure
reliable,trouble-free operation.
COOO
musco.��
D.
Luminaire and Driver-TLC-LED-1500
Driver Data Typical Wiring
Electrical Data
Rated wattage surge'
Per driver 1430 W Protection
Per luminaire 1430 W ----------
_ Controlbr;
Number of luminairesperdrlver ____ 1 Lt Disconnect Fuse
Driver
Starting(inrush)current <40,k 256 its �� lum,mve
_Fuse rating_ _ 15A 1.2' Fuse
UL,IEC ambient temperature rating, SOY(122-F)
electrical components enclosure __
Ingress protection,electrical — IP54 'N (cam)Is neutral then not switched or lased
9 1 Not Present N indoor ir5tailation.
components enclosure
Efftcienty _ -- — 95%
Dimming mode optional
Range,energy consumption __ _ 12-1 OD%
Range,light output 17-100%
Max operating current per 8.86 A 8.52 A 8.06 A 7.71 A 7.39A 6.40 A S.I I A 4.67 A 4.43 A 4.17 A 3.70 A
luminaire'
Footnotes:
1)Rated wattage is the power consumption,including driver efficiency losses,at stabilized operation in 25'C ambient temperature environment.
2)operating current includes allowance for 0.90 minimum power factor,operating temperature,and LED light source manufacturing tokranm.
Notes
1.Use thermal magnetic HID-rated or D-curve circuit breakers.
2.See Musco Control System Summary for circuit information.
i6e0 mm1 —�
L"
—I
ISel mml _
o
])4p se eemm
lase 1 ISSa 1
J
US..n41p9ign petaiNl ILwN en4 DD"�n9•4]Oi9 Nusso Span Liphtinp LLC•ILCIfn ISep 51WR 15 CW•M9919enW 3
musco.
z
�.I
Central Park North Soccer Fields
Oak Brook,It
Lighting System From Hometown to Professional
le I Fixture Summary
•F-1D —"M kkk B•IM6 RZMe 011 WAM1m TIM LOW Clove
S1 S2 B0 80 7 TLC-LED-1503 10.01 kW A
80 7 TLC-LED-1500 01 k'
B
S3-S4 8o' 60 7 TLC-LED-1500 100'1w A
S5-S5 BO' 80 7 TLG -
LED1500
6 so _ Sam kW
FClrcutt Summary
Ckwtt a.•."- LA0 BhbeGh'
A Soc— 40,4 kW 28
B Sccw_r2 40.04 kW 28
801666
T"* W6A' Izws l90 L80 L70 OUMk9
TLC-LED-1500 LED 5700K-75 CBI 143OW 180,000 '81.000 '8'000 '81000 56
Light Level Summary
.cne wme Ckka6MlA Uft Aw W ft-k—
M.N..
BlaGro HOn:Ontai 592 0 32 36463,9 A,B 56
HiQl.ay Pmoemf Line HO._1 0 0 0 000 A. %
Soccer 1 S., Hpnzomel Ilklmin6rce 0.03 0 0 OB 0.00 A 28
$octad Honzamm OLmnlance 40.5 30 49 1.64 1.35 A 28
So 2 Sul'. Honz .filumin6nce 003 0 008 0,130 B 28
Soccer 2 HOn2 'kluminaOce 405 30 50 1,68 1.35 6 29
West Sloe Pmcery Lme Ho,, m 1 0.08 0 043 319.64 A.6 55
\/`/D
Crl
mu ;,✓
We Make It Happen.
ENGINEERED DESIGN By: File#200766 408.20-Feb-20 "Mme• Wm• =«P•n..r�.l,�..,ne��o�x�lmlwsro
S_Lgkkq.LLC.01961.2030 Mnro Swm Lgnnrq.'.:C
PROJECT
' \
EQUIPMENT LIST FOR "AREAS SHOWN Central Park North Soccer Fields
wml
CITY LounoR s� E ATI 111004114G LUM"RE CITY r THIS oTKR Oak Brook,IL
EIFVATIOM 4EGNT TYPE POLE ORO am
sl-s2 so so TLC-LED 15010 717• ._ 7 7 GRID SUMMARY
1 s3-S4 80' 80' TLC-LED-1500 7 7 0
a Tolat 4; .e Name: Soccer(
'This strxtwe utilltes a back-te-back mounting configuranor Size: 336'x 225'
Spacing: 30.0'x 30.0'
ILLUMINATION
MAINfAINEDHORIZONTAl FOOTCANDLES
Entire Grid
Guaranteed Average: 40
2 ! t Scan Average 40.48
Maximum: 49
Minimum: 30
Avg/Min: 1.36
Guaranteed Max/Mln: 2
Max/Min 1.64
UG(adjacent pts): 147
CU Cal
No.of Points: 96
LUMINAIRE
Color/CRL 5700K-75 CRI
Luminaire Output 160,000 lumens
No.of Luminaires: 28
Total Loads 40.04 kW
i umr MamiemrK e
Luirnnaire Type L90 hrs La0 his L70 his
TLC-LED-1500 >81,000 >81,000 >81,000
Rex-Tec oe--v..- :.5ee:um'-ave eatas"rt'or^_etail-
Guaranteed Performance: The ILLUMINATION described
above rs guaranteed per your Musco
Warranty document and includes a 0.95
dirt depreciation factor.
Field Measurements: Individual field measurements may vary from
computer-calculated predictions and should be taken
in accordance with IESNA RP-6-15.
Electrical system Requirements: Refer to Amperage
Draw Chart and/or the"Musco Control System Summary'
for electrical sizing
Installation Requirements:Results assume Y 3%
nominal voltage at line side of the driver and structures
located within 3 feet(lml of design locations
S1 ss ,
000O
MUS
SCALE IN FEET':5C
vole iocanoNsl 9sdmensam are regtiva
tppp•ereeKe poi n(a, We Make It Happen.
ar `�
Not to be reproduced in whole o•par,w•inout the,.•men comem C Musco
ENGINEERED DESIGN By: • Flle#20076640B•20-Feb-20 co^is LpMi q.LLC J,98, 2020 Musco its Ligh!g,LLC
EQUIPMENT Prole Central Park North Soccer Fields
�, LOCATttla SVE 3RAT1 •"Eron'G IAITVPE OLE �1110 Wit Brook,IL
ELEVAT104 %'%n: NKAT PptE SS-S2 SC - 80' TLC-LED450° 7/7• a55.55 fi0' - FO' TLC-LED-1500 7 SUMMARY4 T 4 Name: Soccer 2
This structure utilizes a back-to-back mounting confguration Size: 336'x 225
Spacing: 30.0'x 30,0'
ILLUMINATION
MAIN7A1NEO40R120NTAL FOOTCANDLES
Entire Grid
Guaranteed Average: 40
156 ss S2 Scan Average. 40-52
Maximum 50
Minimum: 30
Avg/Min: 1.37
Guaranteed Max/Min: 2
Max/Min: 1.68
UG(adjacent pts): 1.47
CU: 0.81
No.of points: 96
LUh•1.1AIRE WFORMATION
Color/CRI: S7DDK-75 CRI
Luminaire Output: 160.000 lumens
No.of luminaires: 28
Total Load: 40.04 kW
lumen hMatenance
Lumina,re Type L90 him LSD hrs L70 hrs
TLC-LED-1500 >81,000 >BLD00 A1,0D0
Reoo•t!d ner Ttd-21-11.Sre l u—ar!tlataztxet for dela'Is. -
Guaranteed performance: The ILLUMINATION described
above is guaranteed per your Musco
Warranty document and includes a 0.95
dirt depreciation factor.
Field Measurements: Indaridual field measurements may vary from
computer-ralculated predictions and should be taken
in accordance with IESNA RP-A-15
Electrical System Requirements: Re'er ro Amperage
Draw Chart and/or the-Musco Control System Summary"
for electnca?sizing
Installation Requirements:Results assume±3%
nominal voltage at line side of the driver and structures
located within 3 feet(Im)of design locations.
,� S1
0000
mu
® SCALE IN FEET t:60 vole tocaeon(s) ♦dimeruiom are relative r r
" m°°xterencepdertts)
�' 120' We Make It Happen.
ENGINEERED DESIGN By: •File#200766 408.20-Feb-20 Not roberepr°duce°inPAOr°artminolthe wnnenconsentofk6jwo
Sports Lig ting,LLC tSt981.2020 k1usco Sports Lihtmg,LLC
EQUIPMENT LIST FOR AREAS SHOWN
Central Park North Soccer Fields
^ ^o" >e aauaraN LURtrree �' >srs Oak Brook,IL
e Ifleltl ttN pie pm ixf
2 s1-S2 80' TLGLEMS00 -V? 1, o a
s356 B]' !p• - nciEO.lso° 1
Name: 8bnket Grid
•Ttm Rrur[un udlket a Wd.mLack^wunnrN cvnRau.atbn
Site 336'.225'
Spacing: 20.P.20.0"
MAINTAINED HORt2pH/AL FOOTCpN^.LES
Em re GNd
Spn.,hi t: 6,32
Maximum: 32
o o e n Minimum'. 0
An/Min: 7503.22
Maa/Mm 38463.09
VG(adjacent pK): 61.09
"': 0-21
No.of""M
711
M NAIRE 1.109sath-
Color/CRL 570OK-75CRI
Wou,lum 0ulput. 160000l.-'
,
2 No.of Wmlrrkes: S6
— Total load: 80.06 kW
TIC- '•T. L90 hn 11p Ns L70 nn,•
tEO-1500 >BI.OW >81,000 >81.000
Guarameed Performance:The1LLOMINaTIONies-tsdi
above,s guanmeed per vour Musto
Wxraw doormen[and includes a 0.95
dirt de—sohon I—
_ RkM MeawNmems:Individual field measurements ma,vary from
—out.,talculated predictions and should be taken
ordancevrl[h IESNA RP-615.
1 Ekctrkal System Repuiremems:Refer[o Amperage
Draw Chart and/ar the'Mu Coot of SNtem$u t—ha'
far el-incm siting.
=11ollon Reaulremems:Results assume S 3%
nal voltage at Rue We of the duvet and structures
located within 3 feet(lm)of design Imah ms.
® SCALE IN FEET I:150 Pde bcanaMst Aeim.mlom an 2l.n>. r
We Make It Happen.
D' r54 300'
ENGINEERED DESIGN By:-File#20076640B 20-Feb-20 Nmlpareprpo en.na.apan wmwl m..�rimnc«�a.n1a M„xo
SWrK L9nk•9.LLC.919Bt.2°20 Mlgm$Wrla 1pmrKl,LLC.
ILLUMINATION SUMMARY
EQUIPMENT LIST FOR AREAS SHOWN
Central Park North Soccer Fields
OTs' LOCAnOw SIZE GRA VOUNTWG LVVIWAtPE OTYr THIS OTHER Oak Brook,IL
ELEVATION NEHONT TYPE POLE GMD GRDS
2 51-S2 80' a0' TLCAED-150C :;?•
2 _ 53.54 80 - 1111 80' TLC-LED-1500 T GRID SUMMARY
4 TOTALS 42 28 14 "M W. Soccer I Spin
'This structure utilizes a back-to-back mou^Ong cenfigu"eon Spa": 30.0'
ILLUMINATION SUMMARY �
uCR11CNTAL-'OCTCANOLES
Entire Grid
Scan Average: 0.0266
Maximum: 0.08
Minimum 0.00
0.0 0° No.of Points: 69
0 0 0 0 RE'WORNIATIDN
0.0 Color/CRI: 5700K-75 CRI
Luminaire Output 160,000 lumens
No.of Luminaires: 28
Total Load 40.04 kW
Manr�nancp
Lu-"ins Type _ L90 his j L80 hrs u L70 hrs
TLC-LED-1500 '81,000 >81,000 >81,000
.S6 S2 3 Re^ tec r• -a+ cater"et•o,_tanr
Guaranteed Performance: The ILLUMINATION described
above s guaranteed per your MUSro Warranty
document
Field Measurements: Individual field measurements may vary From
computer-calculated predictions and should be taken
m accordance with IESNA RP-615.
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the'Musco Control System Summary'
For electrical siting.
Installation Requirements:Results assume-3%
nominal voltage at line side of the driver and structures
5
located within 3 feet(1m)of design locations.
1 4
o00o
mu
SCALE IN FEET 1:150 r. r' t
Pole Iecanon(s) +dimensions arc mlaew '
�. t50 Yrc to 0,0 reference po-rttfsl We Make It Happen.
ENGINEERED DESIGN By: a File#200766 40B•20-Feb-20 Not robe•eoroeu:d in+wholec'pan winoutnr.acenconsentatkhtwe
S9o+1S Lighcmg.LLC.1981.2020 Musw Seers Lighting,LLC
ILLUMINATION
.• AREAS SHOWN
Pale Central Park North Soccer Fields
OTY LOCATION WEE3RADE wouN12N6 LUMMME CITY rAS OTHER Oak Brook,IL
LEVATION NEG" TYPE POLE OW lilllp5
2 51.52 8080' 7LC-IED-1500 717• 7 T ._
55-56 80' - 80' TLC-1ED-1500 7 7 0 GRID SUMMARY
4 rol az Z8 14 Name:
"'hi s structure util'zes a back to-back moi,,ting conniguniho- Sxcer2Split
Spadn6: Socc
ILLUMINATION SUMMARY
H0RiZ0NTAL FOOTCANDLES
Entire Grid
San Average: 0.0268
Maximum: M08
Minimum: 0.00
0.0 No.of Points: 69
LUMNAIRE INFORMATION
Color/CRI: 57DDK-75 CRI
Luminaire Output: 160.000 lumens
No.of Luminaires: 28
' Total Load: 40.04 kW
�� Lum r"M,�n•e�.ancn
Luminaire Type L90 hn L80 hn VO his
TLC-LED-1500 >81,000 >81,000 >81.000
6 .52 +^-oorted oe,TM- 1-1i ^�rtan•dam;^e.0`n•n.-a
Guaranteed Performance: The ILLUMINATION described
above is guaranteed per your Musco Warranty
document
Field Measurements: Individual field measurements may vary from
computer-calculated predictions and should be taken
in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer to Amperage
Draw Chart and/o•the"Musco Control System Summary"
for electricab sizing
Installation Requirements:Results assume 3 3%
®�• nominal voltage at line side of the driver and structures
S S1 located within 3 feet I lml of design locations.
OC()O
mu
® SCALE IN FEET 1_150 r
•ole location(sj fP dimeroionsarc relative
" o0.0referenceooimisi We Make It Happen.
ENGINEERED DESIGN By: •File#200766 40B•20-Feb-20 Nollobereproduced i^whole of Pal-V`-vj?lhew0nenconse••tmttusco
Sports LoMrrp.LLC.ID2981.2023 Nus=Sports Cintinp.L'-C
ILLUMINATION
i EQUIPMENT LIST FOR AREAS SHOWN
Central Park North Soccer Fields
otr LOCAL M 91M WADE I wou"TIaG LeteiWK— onr nes oTMEe Oak Brook,IL
EtEyAI M Wart TYR POLE OIaD _ G0.os
2 SI-S2 8o - 80" TLC-LED-15(10 717• la O
a S3-S6 8C' - 80' TLC-LED-1500 7 7 ° GRID SUMMARY
TOTALS NamSid
Raffle: West e Property
This structum utilizes a back-to•back^Ounttng co^figuration 55 D
Spacing:.�}3�0.�0��
ILLUMINATION ■
HORIZONTAL FOOTCANDLES
Entire Grid
Scan Average: 0.0623
Maximum: 0.43
- Minimum: 0.00
No-of Points: 22
LU`.TNA!RE!41FOQr0A-!ON
Color I CRI: 5700K-75 CR I
LummaireOutput- 160,000 lumens
No.of luminaires: 56
Total Load: 80.08 kW
lumen Ma,rrrenarce
Lum"naee Type L90 hrs L60 hrs L70 hn
TLC-LED-r1500 >81,000 ! >81,000 >81,g00
". :1-I'.See umirare Ca�s..ea�,. �^tails
-
6 2
Guaranteed Performance: The ILLUMINATION described
above is guaranteed per your Musco Warranty
document
Field Measurements: Individual field measurements mavvary from
computer-calculated predictions and should be taken
in accordance with IESNA RP-6-15.
Electrical System Requirements: Refer t°Amperage
Draw Chart and/or the"Musco Control System Summary
for electrical sizing
Installation Requirements:Results assume t 3*4
rj nominal voltage at line side of the driver and structures
located within 3 feet f Lm)of design locations.
�O
mu
^SCALE IN FEET 1:200 ,
R Dole tocaoonlsl enuoro an re!an..
200 n°
t4°.°�re en<°mind:, We Make It Happen,
ENGINEERED DESIGN By: •File#200766 40B•20-Feb-20 Not to berevooxed,nwhaeorDan withowthe wrihenconsernofmusco
Spor-.s Light V,LLC 1�1 98'.2020 Musco Sports Lghanq,LLC.
EQUIPMENT LIST FOR AREAS SHOWN
� Central Park North Soccer Fields
QT LOCATION stat ORAOE LUMKAMIE OTTr Tlat DIRER Oak Brook,IL
ELMTM MEOW TYPE POLE dln Olapa
S1-S: 80' - 80' TLC-LED-1500 7/7•
-IC14 0 a
A 53-56 80' - 80' TX-LED-15(100 7 7 0GRISUMMARY
6 TOTAL 56 Sfi 0 Name: Highway property Line
•This structure Lmi,res a track4o-back n ountng configu:anon Spacing: 30.D
ILLUMINATION MARY _
..CRIZONTAL-OCTCANDLES
Entire Grid
Scan Average: 0.0000
y
Maximum: 0.00
Minimum: 0.00
No.of Points: 30
;�M MAf RE'NCGRMATrCN
Color/CRI: 5700K-75 CRI
Lummatre Output 160,000 lumens
No-of Luminaires: 56
Total Load 80.08 kW
i;,�, ..•.taker:+
Lum,naire Type L90 firs I L80 firs L70 firs^"
TLC-LED-1500 >81,000 1 181,000 181,000
^,o-.�rt�-3 ae•T+^ L' See lu—narro datai�eet fnr deta,s.
Guaranteed Performance: The ILLUMINATION described
above-s guaranteed per vour Musco tVarranty
document
Field Measurements: Individual field measurements may vary from
computer-calculated predictions and should betaken
m accordance with IESNA RP-6-15
Electrical System Requirements: Refer to Amperage
Draw Chart and/o•the"Musco Control System Summary"
for electrical sizing.
Installation Requirements: Results assume t 3%
S4 nominal voltage at line side of the driver and structures
located within 3 feet I1mI of design locations
MUS!SCALE IN FEET T:200
Vololocanon(s) +dimensions are relative
200'
to°.orefe.enceDoint(s) We Make It Happen.
ate.
ENGINEERED DESIGN By: -File#20D766 40B-20-Feb-20 NOT to be reproduced n wrVe or part wn'oul Me x !len cent of Musco
Soars Lght-c.LLC �tr98•.2020 Musco Soors L-oh".LLC
Ordinance 2020-ZO-V-EX-S-1601
1315 and 1425 Kensington Road-Variation
PINS:6-26-102-008 and 06-26-102-009
Page 7 of 8
Exhibit C
Unconditional Agreement and Consent
WHEREAS,a petition has been submitted by the Oak Brook Park District,the Property Owner
(hereinafter referred to as the"Owned'),of the property located at 1315 and 1425 Kensington Road,Oak
Brook,which is legally described in Exhibit A attached hereto and incorporated herein(hereinafter referred
to as the"Subject Property')which is zoned CR,Conservation,requesting approval of a variation from
Section 13-5-4D to permit six(6)light poles at a height of eighty feet(80')on the Subject Property in and
around the ball fields to provide for use of said fields during night time sports activities and in order to
provide adequate lighting for the users of said fields owner is requesting certain variations to the Village's
zoning regulations for said purposes as set for the herein(hereinafter referred to as the"Variation');
WHEREAS, Ordinance No.2020-ZO-V-EX-S-1601, adopted by the President and Board of
Trustees of the Village of Oak Brook on April 28,2020(hereinafter referred to as the"Ordinance"),grants
approval of the Variation,subject to certain modifications,conditions,restrictions,and provisions;and
WHEREAS,the Ordinance provides,among other things,that the Ordinance will be of no force or
effect unless and until the Applicant files this Unconditional Agreement and Consent with the Village Clerk.
NOW,THEREFORE,the Applicant hereby agree and covenants as follows:
1. The Owner hereby unconditionally agrees to accept,consent to,and abide by all of the terms,
conditions,restrictions,and provisions of the Ordinance.
2. The Owner acknowledges that:(i)public notices and hearings have been properly given and held
with respect to the adoption of the Ordinance;(ii)the Owner has considered the possibility that the
Variation granted by the Ordinance may be revoked if the Owner does not comply with the
Ordinance;and(iii)The Owner agrees not to challenge any such revocation on the grounds of any
procedural infirmity or a denial of any procedural right.
3. The Owner acknowledges and agrees that the Village is not and will not be,in any way,liable for
any damages or injuries that may be sustained as a result of the Village's issuance of any permits
for the use of the Property and that the Village's issuance of any such permits does not,and will
not,in any way,be deemed to insure the Owner against damage or injury of any kind and at any
time.
4. The Owner agrees to and does hereby hold harmless and indemnify the Village, the Village's
corporate authorities,and all Village elected and appointed officials,officers,employees,agents,
representatives,and attorneys,from any and all claims that may,at any time,be asserted against
any of such parties in connection with the operation and use of the Property, or the Village's
adoption of the Ordinance.
[Signature page follows]
Ordinance 2020-ZO-V-EX-S-1601
1315 and 1425 Kensington Road-Variation
PINS: 6-26-102-008 and 06-26-102-009
Page 8 of 8
IN WITNESS WHEREOF,Owner executed this Unconditional Agreement and Consent on this day of
20_.
Owner:
Oak Brook Park District
State of Illinois )
County of DuPage )
I, a Notary Public in and for the County and State aforesaid do
hereby certify that personally known to me,and that he appeared before me this
day of 2020 and acknowledged that he personally executed this instrument.
(SEAL) Notary Public